SINAMICS S120 drive system<br />

Line Modules and line-side components<br />

Smart Line Modules in booksize format<br />

■ Integration<br />

© <strong>Siemens</strong> AG <strong>2013</strong><br />

3<br />

L1<br />

L2<br />

L3<br />

PE<br />

1L1<br />

1L2<br />

1L3<br />

PE<br />

ext.<br />

24 V<br />

+ M<br />

Main switch<br />

X24<br />

+<br />

M<br />

Line contactor<br />

Fuses<br />

24 V<br />

DI<br />

2) CU<br />

DO<br />

CU<br />

2)<br />

3)4)<br />

9)<br />

DO<br />

CU<br />

1)<br />

2)<br />

DI<br />

CU<br />

DI<br />

CU<br />

X<strong>21</strong><br />

1<br />

2<br />

3<br />

4<br />

DO, Ready<br />

DO, Warning I*t<br />

EP +24 V<br />

EP M<br />

Smart Line<br />

Module<br />

+<br />

M<br />

DCP<br />

DCN<br />

Line filter<br />

Line reactor<br />

8)<br />

7)<br />

2)<br />

DO<br />

CU<br />

6) M<br />

5)<br />

DO<br />

CU<br />

X22<br />

1<br />

2<br />

3<br />

4<br />

+ 24 V<br />

DI, Disable<br />

DI, Reset<br />

M1<br />

LEDs<br />

U1 V1 W1<br />

READY<br />

DC LINK<br />

G_D<strong>21</strong>1_EN_00286<br />

7)<br />

X1<br />

U1<br />

V1<br />

W1<br />

1) Leading NC contact t >10 ms, 24 V DC and ground must be connected for operation.<br />

2) DI/DO, controlled by the Control Unit.<br />

3) No additional load permitted downstream of the line contactor.<br />

4) The current carrying capacity of the digital output (DO) must be taken into account; an output interface element may have to be used.<br />

5) Digital output (DO) = High means: feedback deactivated (a jumper can be inserted between X22 pins 1 and 2 for permanent deactivation).<br />

6) X22 pin 4 must be connected to ground (ext. 24 V).<br />

7) Contacting via mounting back panel or shield panels according to EMC Installation Guidelines.<br />

8) 5 kW and 10 kW line filters via shield connection<br />

9) Signal output to prevent backlash of the DC 24 V supply on the EP terminal.<br />

Connection example of 5 kW and 10 kW Smart Line Modules in booksize format<br />

3/90 <strong>Siemens</strong> <strong>PM</strong> <strong>21</strong> · <strong>2013</strong>