© <strong>Siemens</strong> AG <strong>2013</strong><br />

SINAMICS S120 drive system<br />

Motor Modules<br />

Single Motor Modules in booksize format<br />

■ Technical specifications (continued)<br />

DC link voltage<br />

Single Motor Module in booksize format<br />

510 … 720 V DC<br />

Internal air cooling 6SL3120-... 1TE13-0AA3 1TE15-0AA3 1TE<strong>21</strong>-0AA3 1TE<strong>21</strong>-8AA3 1TE23-0AA3<br />

External air cooling 6SL31<strong>21</strong>-... 1TE13-0AA3 1TE15-0AA3 1TE<strong>21</strong>-0AA3 1TE<strong>21</strong>-8AA3 1TE23-0AA3<br />

Cold plate cooling 6SL3126-... 1TE13-0AA3 1TE15-0AA3 1TE<strong>21</strong>-0AA3 1TE<strong>21</strong>-8AA3 1TE23-0AA3<br />

Liquid cooling 6SL3125-... – – – – –<br />

Internal/external air cooling<br />

• Power loss 1)<br />

- Maximum losses kW 0.05 0.07 0.1 0.19 0.31<br />

with internal air cooling<br />

in control cabinet<br />

- Typical losses<br />

kW 0.03 0.04 0.06 0.14 0.26<br />

in control cabinet 2) with internal air cooling<br />

- With external air cooling, kW 0.035/0.015 0.04/0.03 0.055/0.045 0.1/0.09 0.1/0.<strong>21</strong><br />

int./ext. 1)<br />

• Cooling air requirement m 3 /s (ft 3 /s) 0.008 (0.283) 0.008 (0.283) 0.008 (0.283) 0.008 (0.283) 0.016 (0.565)<br />

• Sound pressure level dB < 60 < 60 < 60 < 60 < 60<br />

L pA (1 m)<br />

Cold plate cooling<br />

• Power loss, int./ext. 1) kW 0.025/0.02 0.035/0.035 0.045/0.05 0.08/0.1 0.085/0.22<br />

• Thermal resistance R th K/W 0.175 0.175 0.175 0.175 0.075<br />

Motor connection<br />

U2, V2, W2<br />

Connector (X1) 3) ,<br />

max. 30 A<br />

Shield connection Integrated in<br />

connector (X1)<br />

Connector (X1) 3) ,<br />

max. 30 A<br />

Integrated in<br />

connector (X1)<br />

Connector (X1) 3) ,<br />

max. 30 A<br />

Integrated in<br />

connector (X1)<br />

Connector (X1) 3) ,<br />

max. 30 A<br />

Integrated in<br />

connector (X1)<br />

Connector (X1) 3) ,<br />

max. 30 A<br />

Integrated in<br />

connector (X1)<br />

PE connection M5 screw M5 screw M5 screw M5 screw M5 screw<br />

Motor brake connection Integrated into<br />

the plug-in motor<br />

connector (X1),<br />

24 V DC, 2 A<br />

Motor cable length, max.<br />

Integrated into<br />

the plug-in motor<br />

connector (X1),<br />

24 V DC, 2 A<br />

Integrated into<br />

the plug-in motor<br />

connector (X1),<br />

24 V DC, 2 A<br />

Integrated into<br />

the plug-in motor<br />

connector (X1),<br />

24 V DC, 2 A<br />

Integrated into<br />

the plug-in motor<br />

connector (X1),<br />

24 V DC, 2 A<br />

• Shielded m (ft) 50 (164) 50 (164) 50 (164) 70 (230) 100 (328)<br />

• Unshielded m (ft) 75 (246) 75 (246) 75 (246) 100 (328) 150 (492)<br />

Degree of protection IP20 IP20 IP20 IP20 IP20<br />

Dimensions<br />

• Width mm (in) 50 (1.97) 50 (1.97) 50 (1.97) 50 (1.97) 100 (3.94)<br />

•Height mm (in) 380 (15.0) 380 (15.0) 380 (15.0) 380 (15.0) 380 (15.0)<br />

•Depth<br />

- With internal air cooling mm (in) 270 (10.6) 270 (10.6) 270 (10.6) 270 (10.6) 270 (10.6)<br />

- With external air cooling,<br />

on/behind mounting<br />

surface<br />

mm (in) 226/66.5<br />

(8.90/2.62)<br />

226/66.5<br />

(8.90/2.62)<br />

226/66.5<br />

(8.90/2.62)<br />

226/66.5<br />

(8.90/2.62)<br />

226/66.5<br />

(8.90/2.62)<br />

- With cold plate cooling mm (in) 226 (8.90) 226 (8.90) 226 (8.90) 226 (8.90) 226 (8.90)<br />

Weight, approx.<br />

• With internal air cooling kg (lb) 5.0 (11) 5.0 (11) 5.0 (11) 5.0 (11) 6.9 (15)<br />

• With external air cooling kg (lb) 5.7 (13) 5.7 (13) 5.7 (13) 5.7 (13) 8.5 (19)<br />

• With cold plate cooling kg (lb) 4.2 (9) 4.2 (9) 4.5 (10) 4.5 (10) 6.1 (13)<br />

3<br />

1) Power loss of Motor Module at rated power including losses of 24 V DC electronics power supply.<br />

2) At max. motor cable length 30 m (98.4 ft), pulse frequency 4 kHz and DC link voltage 540 … 600 V.<br />

3) Connector not included in scope of supply, see Accessories.<br />

<strong>Siemens</strong> <strong>PM</strong> <strong>21</strong> · <strong>2013</strong><br />

3/147

Hooray! Your file is uploaded and ready to be published.

Saved successfully!