SINAMICS S120 drive system<br />

Line Modules and line-side components<br />

Active Line Modules in booksize format<br />

© <strong>Siemens</strong> AG <strong>2013</strong><br />

3<br />

■ Technical specifications (continued)<br />

Line voltage<br />

Active Line Module in booksize format<br />

380 … 480 V 3 AC<br />

Internal air cooling 6SL3130-... 7TE<strong>21</strong>-6AA3 7TE23-6AA3 7TE25-5AA3 7TE28-0AA3 7TE31-2AA3<br />

External air cooling 6SL3131-... 7TE<strong>21</strong>-6AA3 7TE23-6AA3 7TE25-5AA3 7TE28-0AA3 7TE31-2AA3<br />

Cold plate cooling 6SL3136-... 7TE<strong>21</strong>-6AA3 7TE23-6AA3 7TE25-5AA3 7TE28-0AA3 7TE31-2AA3<br />

Liquid cooling 6SL3135-... – – – – 7TE31-2AA3<br />

Feed/feedback power<br />

• Rated power P rated<br />

- At 380 V 3 AC<br />

- At 460 V 3 AC 5) kW<br />

(HP)<br />

16<br />

(18)<br />

36<br />

(40)<br />

55<br />

(60)<br />

80 (64 1) )<br />

(100 (75 1) )<br />

120 (84 1) )<br />

(150 (100 1) )<br />

• For S6 duty P S6 (40 %) kW <strong>21</strong> 47 71 106 (85 1) ) 145 (116 1) )<br />

• P max kW 35 70 91 (110) 2) ) 131 175<br />

DC link current<br />

• At 600 V DC A 27 60 92 134 200<br />

• For S6 duty (40 %) A 35 79 1<strong>21</strong> 176 244<br />

•Maximum A 59 117 152 (176 2) ) <strong>21</strong>8 292<br />

Input current<br />

• Rated current<br />

A 26/25/<strong>21</strong> 58/55/46 88/84/70 128/122/102 192/182/152<br />

at 380/400/480 V 3 AC<br />

• For S6 duty (40 %)<br />

A 32 71 108 161 220<br />

at 400 V<br />

• At 400 V max. A 54 107 139 (168 2) ) 200 267<br />

Current requirement<br />

A 1.1 1.5 1.9 2.0 2.5 (2.1 3) )<br />

24 V DC electronics<br />

power supply, max.<br />

Current carrying capacity<br />

• 24 V DC busbars A 20 20 20 20 20<br />

• DC link busbars A 100 200 200 200 200<br />

DC link capacitance<br />

• Active Line Module μF 710 1410 1880 2820 3995<br />

• Drive line-up, max. μF 20000 20000 20000 20000 20000<br />

Internal/external air cooling<br />

• Power loss 4)<br />

- Total power loss for<br />

kW 0.29 0.67 0.95 1.39 2.26<br />

cooling types:<br />

internal air cooling,<br />

external air cooling;<br />

cold plate cooling,<br />

liquid cooling<br />

- With external air cooling, kW 0.09/0.2 0.17/0.5 0.25/0.7 0.3/1.0 0.55/1.71<br />

int./ext.<br />

• Cooling air requirement m 3 /s (ft 3 /s) 0.016 (0.565) 0.031 (1.095) 0.044 (1.554) 0.144 (5.085) 0.144 (5.085)<br />

• Sound pressure level dB < 60 < 65 < 60 < 75 < 75<br />

L pA (1 m)<br />

Cold plate cooling<br />

• Power loss, int./ext. 4) kW 0.07/0.<strong>21</strong> 0.13/0.52 0.19/0.74 0.3/1.1 0.46/1.8<br />

• Thermal resistance R th K/W 0.075 0.055 0.05 0.028 0.028<br />

1) In the case of cold plate cooling, derating is necessary due to heat transfer to the external heat sink.<br />

2) Higher peak power is possible in combination with the Active Interface Module 6SL3100-0BE25-5AB0 (for operating cycle constraints,<br />

see SINAMICS S120 Manual).<br />

3) For 6SL3135-7TE31-2AA3.<br />

4) Power loss of Active Line Module at rated output including losses of 24 V DC electronics power supply.<br />

5) Nominal HP ratings are provided for ease of assigning components only. The Line Module outputs are dependent on the Motor Module loading and are to be<br />

dimensioned accordingly.<br />