30.12.2014 Views

Catalog PM 21 2013 - Siemens Industry, Inc.

Catalog PM 21 2013 - Siemens Industry, Inc.

Catalog PM 21 2013 - Siemens Industry, Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

© <strong>Siemens</strong> AG <strong>2013</strong><br />

SINAMICS S120 drive system<br />

Motor Modules<br />

Single Motor Modules in chassis format<br />

■ Technical specifications<br />

Single Motor Module in chassis format<br />

6SL3320-1T...<br />

DC link voltage<br />

(up to 2000 m (6562 ft) above sea level)<br />

Output frequency<br />

510 ... 720 V DC (line supply voltage 380 ... 480 V 3 AC) or<br />

675 ... 1035 V DC (line supply voltage 500 ... 690 V 3 AC)<br />

• Control type Servo 0 … 650 Hz 1)<br />

• Control type Vector 0 … 300 Hz 1)<br />

• Control type V/f 0 … 300 Hz 1)<br />

Electronics power supply 24 V DC -15 %/+20 %<br />

Type of cooling<br />

Internal air cooling,<br />

power units with forced air cooling using a built-in fan<br />

Permissible ambient and coolant temperature (air)<br />

during operation for line-side components,<br />

Line Modules and Motor Modules<br />

Installation altitude<br />

Conformity<br />

Approvals, according to<br />

Safety Integrated<br />

0 … 40 °C (32 … 104 °F) without derating,<br />

> 40 … 55 °C (104 …131 °F) see derating characteristics<br />

Up to 2000 m (6562 ft) above sea level without derating,<br />

> 2000 ... 4000 m (6562 ... 13124 ft) above sea level,<br />

see derating characteristics<br />

CE (Low Voltage and EMC Directives)<br />

cULus<br />

(510 ... 720 V DC Motor Modules only)<br />

Safety Integrity Level 2 (SIL2) acc. to IEC 61508, Performance Level d (PLd)<br />

acc. to ISO 13849-1 and Control Category 3 acc. to ISO 13849-1 or EN 954-1.<br />

For further information see chapter Safety Integrated.<br />

3<br />

1) Note the correlation between max. output frequency, pulse frequency and current derating. (current controller clock cycle 250 μs; pulse frequency 4 kHz,<br />

see characteristic curves for current derating).<br />

For further information, see chapter System description – Dimensioning.<br />

<strong>Siemens</strong> <strong>PM</strong> <strong>21</strong> · <strong>2013</strong><br />

3/155

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!