■ Overview<br />

© <strong>Siemens</strong> AG <strong>2013</strong><br />

SINAMICS S120 drive system<br />

Load-side power components<br />

Motor reactors for chassis format<br />

Motor reactors reduce the voltage loading on the motor<br />

windings. At the same time, the capacitive charge/discharge<br />

currents that place an additional load on the power unit when<br />

long motor cables are used are reduced. The maximum<br />

permissible output frequency when a motor reactor is used<br />

is 150 Hz.<br />

The motor reactor must be installed as close as possible to the<br />

Motor Module or Power Module. Up to 2 motor reactors can be<br />

connected in series.<br />

3<br />

■ Technical specifications<br />

DC link voltage 510 ... 720 V DC<br />

or line voltage 380 … 480 V 3 AC<br />

Motor reactor (for pulse frequencies of 2 kHz to 4 kHz)<br />

6SL3000-<br />

2BE32-1AA0<br />

6SL3000-<br />

2BE32-6AA0<br />

6SL3000-<br />

2BE33-2AA0<br />

6SL3000-<br />

2BE33-8AA0<br />

6SL3000-<br />

2BE35-0AA0<br />

Rated current A <strong>21</strong>0 260 310 380 490<br />

Rated inductance μH 53 40 24 <strong>21</strong> 19<br />

Power loss kW 0.486 0.5 0.47 0.5 0.5<br />

Line/load connection<br />

Flat connector<br />

for M10 screw<br />

Flat connector<br />

for M10 screw<br />

Flat connector<br />

for M10 screw<br />

Flat connector<br />

for M10 screw<br />

Flat connector<br />

for M12 screw<br />

PE connection M8 screw M8 screw M8 screw M8 screw M8 screw<br />

Max. cable length between<br />

motor reactor and motor<br />

(number of reactors in series) (1) (2) (1) (2) (1) (2) (1) (2) (1) (2)<br />

• Shielded m (ft) 300<br />

(984)<br />

525<br />

(1722)<br />

300<br />

(984)<br />

525<br />

(1722)<br />

300<br />

(984)<br />

525<br />

(1722)<br />

300<br />

(984)<br />

525<br />

(1722)<br />

300<br />

(984)<br />

525<br />

(1722)<br />

• Unshielded m (ft) 450<br />

(1476)<br />

787<br />

(2582)<br />

450<br />

(1476)<br />

787<br />

(2582)<br />

450<br />

(1476)<br />

787<br />

(2582)<br />

450<br />

(1476)<br />

787<br />

(2582)<br />

450<br />

(1476)<br />

Degree of protection IP00 IP00 IP00 IP00 IP00<br />

Dimensions<br />

• Width mm (in) 300 (11.8) 300 (11.8) 300 (11.8) 300 (11.8) 300 (11.8)<br />

•Height mm (in) 285 (11.2) 315 (12.4) 285 (11.2) 285 (11.2) 365 (14.4)<br />

•Depth mm (in) 257 (10.1) 277 (10.9) 257 (10.1) 277 (10.9) 277 (10.9)<br />

Weight, approx. kg (lb) 66 (145) 66 (145) 66 (145) 73 (161) 100<br />

(220)<br />

Approvals, according to cURus cURus cURus cURus cURus<br />

Suitable for<br />

Single Motor Module<br />

chassis format<br />

Type 6SL3320-<br />

1TE32-1AA3<br />

6SL3320-<br />

1TE32-6AA3<br />

6SL3320-<br />

1TE33-1AA3<br />

6SL3320-<br />

1TE33-8AA3<br />

6SL3320-<br />

1TE35-0AA3<br />

Suitable for<br />

Power Module<br />

in chassis format<br />

• Rated current<br />

of Motor Module<br />

or Power Module<br />

• Type rating<br />

of Motor Module<br />

or Power Module<br />

Type<br />

6SL3310-<br />

1TE32-1AA3<br />

6SL3310-<br />

1TE32-6AA3<br />

6SL3310-<br />

1TE33-1AA3<br />

6SL3310-<br />

1TE33-8AA3<br />

A <strong>21</strong>0 260 310 380 490<br />

6SL3310-<br />

1TE35-0AA3<br />

kW (HP) 110 (150) 132 (200) 160 (250) 200 (300) 250 (400)<br />

787<br />

(2582)<br />

<strong>Siemens</strong> <strong>PM</strong> <strong>21</strong> · <strong>2013</strong><br />

3/203