© <strong>Siemens</strong> AG <strong>2013</strong><br />
SINAMICS S120 drive system<br />
DC link components<br />
Voltage Clamping Module in booksize format<br />
■ Overview<br />
■ Technical specifications<br />
DC link voltage<br />
510 ... 720 V DC<br />
Voltage Clamping Module<br />
in booksize format<br />
(Internal air cooling)<br />
6SL3100-1VE00-0AA0<br />
Current carrying capacity<br />
• 24 V DC busbars<br />
20 A<br />
• DC link busbars<br />
100 A<br />
PE connection<br />
M5 screw<br />
Grounding<br />
Screw terminal<br />
• Conductor cross-section 4 … 16 mm 2<br />
Power loss, approx.<br />
50 W<br />
Dimensions<br />
• Width<br />
50 mm (1.97 in)<br />
•Height<br />
380 mm (15.0 in)<br />
• Depth, with spacer<br />
270 mm (10.6 in)<br />
(included in scope of supply)<br />
Weight, approx.<br />
3.1 kg (7 lb)<br />
Approvals, according to cULus<br />
3<br />
Voltage Clamping Module in booksize format<br />
Oscillations to ground potential can occur in drive line-ups<br />
with total cable lengths (sum of all motor and DC link cables) of<br />
> 350 m (1148 ft) (shielded) or 560 m (1837 ft) (unshielded).<br />
The Voltage Clamping Module damps these oscillations,<br />
thereby allowing a total cable length of 630/850 m (2067/2789 ft)<br />
(shielded/unshielded) to be used in booksize format drive lineups<br />
in combination with a Smart Line Module with application of<br />
derating, see derating characteristics for Smart Line Modules, or<br />
1000/1500 m (3281/49<strong>21</strong> ft) (shielded/unshielded) in combination<br />
with a Basic Line Module.<br />
With total cable lengths of > 350 m (1148 ft), the limit values of<br />
Category C2 defined in EN 61800-3 can be exceeded.<br />
VCM Voltage Clamping Modules may be operated only in<br />
networks with grounded neutral (TN system).<br />
Where possible, the Voltage Clamping Module should be<br />
mounted next to the Line Module and connected to the voltagesource<br />
DC link via the integrated DC busbar.<br />
■ Selection and ordering data<br />
Description<br />
Voltage Clamping Module<br />
in booksize format<br />
Accessories for re-ordering<br />
Warning labels in 30 languages<br />
This set of foreign language warning<br />
labels can be placed on top of the<br />
standard German or English signs.<br />
A set of labels is supplied with the units.<br />
One sign in each of the following<br />
languages is provided in each set:<br />
BG, CN, CZ, DE, DK, EE, ES, FI, FR,<br />
GB, GR, HU, IE, IS, IT, JP, KR, LT, LV,<br />
MT, NL, NO, PL, PT, RO, RU, SE, SI,<br />
SK, TR<br />
Order No.<br />
6SL3100-1VE00-0AA0<br />
6SL3166-3AB00-0AA0<br />
■ Design<br />
The Voltage Clamping Module features the following connections<br />
and interfaces as standard:<br />
• 2 DC link connections via integrated DC link busbars<br />
• 1 connection for functional ground<br />
• 2 PE (protective earth) connections<br />
The scope of supply of the Voltage Clamping Modules includes:<br />
• Jumper for connecting the 24 V DC busbar to the adjacent<br />
Motor Module<br />
• 1 set of warning signs in 30 languages<br />
<strong>Siemens</strong> <strong>PM</strong> <strong>21</strong> · <strong>2013</strong><br />