© <strong>Siemens</strong> AG <strong>2013</strong><br />
SINAMICS S120 drive system<br />
DC link components<br />
Braking Modules in chassis format<br />
■ Technical specifications (continued)<br />
DC link voltage<br />
Braking Module in chassis format<br />
890 ... 1035 V DC<br />
6SL3300-1AH31-3AA0 6SL3300-1AH32-5AA0 6SL3300-1AH32-5BA0<br />
Power<br />
• Rated power P DB kW 25 50 50<br />
• Peak power P 15 kW 125 250 250<br />
•Power P 20 kW 100 200 200<br />
•Power P 40 kW 50 100 100<br />
Activation thresholds<br />
(adjustable via DIP switch)<br />
V 1153 (factory setting)<br />
or 1070<br />
1153 (factory setting)<br />
or 1070<br />
1153 (factory setting)<br />
or 1070<br />
Cable length<br />
m (ft) 100 (328) 100 (328) 100 (328)<br />
to braking resistor, max.<br />
Digital inputs<br />
in accordance with IEC 61131-2 Type 1<br />
• Voltage V -3 … +30 -3 … +30 -3 … +30<br />
• Low level (an open digital input is V -3 … +5 -3 … +5 -3 … +5<br />
interpreted as "low")<br />
• High level V 15 … 30 15 … 30 15 … 30<br />
• Current consumption at 24 V DC, typ. mA 10 10 10<br />
• Conductor cross-section, max. mm 2 1.5 1.5 1.5<br />
Digital outputs<br />
(sustained short-circuit strength)<br />
• Voltage V DC 24 DC 24 DC 24<br />
• Load current<br />
mA 500 500 500<br />
per digital output, max.<br />
• Conductor cross-section, max. mm 2 1.5 1.5 1.5<br />
Connection<br />
M8 screw M8 screw M8 screw<br />
R1/R2<br />
• Conductor cross-section, max. mm 2 35 50 50<br />
Weight, approx. kg (lb) 3.6 (8) 7.3 (16) 7.5 (16.5)<br />
Approvals, according to – – –<br />
Suitable for installation<br />
in an air-cooled Motor Module or<br />
Line Module<br />
Frame<br />
size<br />
FX/FB GX/GB 1) HX/JX<br />
3<br />
■ Selection and ordering data<br />
Description<br />
DC link voltage 510 … 720 V DC<br />
Frame size FX,<br />
25 kW/125 kW<br />
Braking Module<br />
in chassis format<br />
Order No.<br />
6SL3300-1AE31-3AA0<br />
Description<br />
Accessories<br />
Cable harness set<br />
For mounting a Braking Module of<br />
frame size GX into a Basic Line Module of<br />
frame size GB<br />
Order No.<br />
6SL3366-2NG00-0AA0<br />
Frame size GX,<br />
50 kW/250 kW<br />
Frame sizes HX and JX,<br />
50 kW/250 kW<br />
DC link voltage 675 … 900 V DC<br />
Frame size FX,<br />
25 kW/125 kW<br />
Frame size GX,<br />
50 kW/250 kW<br />
6SL3300-1AE32-5AA0<br />
6SL3300-1AE32-5BA0<br />
6SL3300-1AF31-3AA0<br />
6SL3300-1AF32-5AA0<br />
Warning labels in 30 languages<br />
This set of foreign language warning<br />
labels can be placed on top of the<br />
standard German or English signs.<br />
A set of labels is supplied with the units.<br />
One sign in each of the following<br />
languages is provided in each set:<br />
BG, CN, CZ, DE, DK, EE, ES, FI, FR,<br />
GB, GR, HU, IE, IS, IT, JP, KR, LT, LV,<br />
MT, NL, NO, PL, PT, RO, RU, SE, SI,<br />
SK, TR<br />
6SL3166-3AB00-0AA0<br />
Frame sizes HX and JX,<br />
50 kW/250 kW<br />
6SL3300-1AF32-5BA0<br />
DC link voltage 890 … 1035 V DC<br />
Frame size FX,<br />
25 kW/125 kW<br />
6SL3300-1AH31-3AA0<br />
Frame size GX,<br />
50 kW/250 kW<br />
6SL3300-1AH32-5AA0<br />
Frame sizes HX and JX,<br />
50 kW/250 kW<br />
6SL3300-1AH32-5BA0<br />
1) Cable harness set 6SL3366-2NG00-0AA0 is required to connect the<br />
Braking Module to a Basic Line Module of frame size GB.<br />
<strong>Siemens</strong> <strong>PM</strong> <strong>21</strong> · <strong>2013</strong><br />
3/185