Catalog PM 21 2013 - Siemens Industry, Inc.
Catalog PM 21 2013 - Siemens Industry, Inc.
Catalog PM 21 2013 - Siemens Industry, Inc.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
SINAMICS S120 drive system<br />
DC link components<br />
Braking Module in booksize compact format<br />
© <strong>Siemens</strong> AG <strong>2013</strong><br />
3<br />
■ Overview<br />
Braking Module in booksize compact format<br />
A Braking Module and the matching external braking resistor are<br />
required to bring drives to a controlled standstill in the event of<br />
a power failure (e.g. emergency retraction or EMERGENCY STOP<br />
category 1) or limit the DC link voltage for brief periods of<br />
generator operation, e.g. when the regenerative feedback<br />
capability of the Line Module is deactivated. The Braking Module<br />
includes the power electronics and the associated control circuit.<br />
During operation, the DC link power is converted into heat loss<br />
in an external braking resistor. Braking Modules function autonomously.<br />
A number of Braking Modules in booksize compact<br />
format can be operated in parallel. In this case, each Braking<br />
Module must have its own braking resistor. Braking Modules in<br />
booksize compact format can also be used for rapid discharge of<br />
the DC link.<br />
■ Design<br />
The Braking Modules in booksize compact format can be<br />
integrated in drive line-ups in booksize and booksize compact<br />
formats with internal air cooling and cold plate cooling.<br />
The Braking Module in booksize compact format features the<br />
following connections and interfaces as standard:<br />
• 2 DC link connections via integrated DC link busbars<br />
• 2 electronics power supply connections via<br />
integrated 24 V DC bars<br />
• Connector X1 for connecting the braking resistor<br />
• Connection for thermostatic switch for monitoring the braking<br />
resistor<br />
• 4 DIP switches for setting the operating threshold, selecting<br />
the braking resistor and the cooling method for the Braking<br />
Module<br />
• 2 digital inputs (disable Braking Module/acknowledge faults<br />
and rapid discharge of DC link)<br />
• 3 digital outputs (Braking Module disabled,<br />
prewarning from I × t monitor and set activation threshold)<br />
• 2 PE (protective earth) connections<br />
The status of the Braking Module is indicated via two 2-color<br />
LEDs.<br />
■ Integration<br />
+<br />
M<br />
Braking Module<br />
+<br />
M<br />
24 V DC busbars<br />
DCP<br />
DCN<br />
DCP<br />
DCN<br />
DC link busbars<br />
Max. cable length: 10 m (32.8 ft)<br />
X<strong>21</strong><br />
X1<br />
1<br />
DI, inhibit Braking Module<br />
R1<br />
1<br />
2 DI, DC link fast discharge<br />
R2<br />
2<br />
3 DO, „0 V“ = prewarning Ixt-shutdown<br />
4<br />
DO, „0 V“ = fault/Braking Module inhibited<br />
X22<br />
5<br />
M<br />
T1<br />
1<br />
6<br />
M<br />
T2<br />
2<br />
Braking resistor<br />
G_D<strong>21</strong>1_EN_00270<br />
S1<br />
Selection<br />
- Activation threshold<br />
- Braking resistor with/without<br />
- temperature switch<br />
- Cooling method<br />
=<br />
=<br />
DO Vop<br />
5<br />
Selected activation<br />
threshold<br />
High: 410 V DC<br />
Low: 775 V DC<br />
Connection example of Braking Module in booksize compact format<br />
3/178 <strong>Siemens</strong> <strong>PM</strong> <strong>21</strong> · <strong>2013</strong>