© <strong>Siemens</strong> AG <strong>2013</strong><br />

SINAMICS S120 drive system<br />

Line Modules and line-side components<br />

Active Line Modules in booksize format<br />

■ Technical specifications (continued)<br />

.<br />

Line voltage<br />

Active Line Module in booksize format<br />

380 … 480 V 3 AC<br />

Internal air cooling 6SL3130-... 7TE<strong>21</strong>-6AA3 7TE23-6AA3 7TE25-5AA3 7TE28-0AA3 7TE31-2AA3<br />

External air cooling 6SL3131-... 7TE<strong>21</strong>-6AA3 7TE23-6AA3 7TE25-5AA3 7TE28-0AA3 7TE31-2AA3<br />

Cold plate cooling 6SL3136-... 7TE<strong>21</strong>-6AA3 7TE23-6AA3 7TE25-5AA3 7TE28-0AA3 7TE31-2AA3<br />

Liquid cooling 6SL3135-... – – – – 7TE31-2AA3<br />

Feed/feedback power<br />

3<br />

• Rated power P rated<br />

- At 380 V 3 AC<br />

- At 460 V 3 AC 7)<br />

Liquid cooling 2)<br />

kW<br />

(HP)<br />

16<br />

(18)<br />

36<br />

(40)<br />

55<br />

(60)<br />

80 (64 1) )<br />

(100 (75 1) )<br />

120 (84 1) )<br />

(150 (100 1) )<br />

• Power loss, int./ext. 3) kW – – – – 0.46/1.8<br />

- Rated volumetric flow for l/min – – – – 8<br />

drop 4) water at 70 kPa pressure<br />

- Volume of liquid, internal ml – – – – 100<br />

- Coolant temperature, max.<br />

- Without derating °C (°F) – – – – 45 (113)<br />

- With derating °C (°F) – – – – 50 (122)<br />

- Sound pressure level<br />

L pA (1 m)<br />

dB – – – – < 73<br />

Line connection<br />

U1, V1, W1<br />

Screw-type<br />

terminals (X1)<br />

M6 screw<br />

studs (X1)<br />

M8 screw<br />

studs (X1)<br />

M8 screw<br />

studs (X1)<br />

M8 screw<br />

studs (X1)<br />

• Conductor cross-section, max. mm 2 2.5 … 10 2.5 … 50 2.5 … 95.2 × 35 2.5 … 120.2 × 50 2.5 … 120.2 × 50<br />

Shield connection Integrated in the See Accessories See Accessories See Accessories See Accessories<br />

connector<br />

PE connection M5 screw M6 screw M6 screw M8 screw M8 screw<br />

Cable length, max.<br />

Total of all motor cables and<br />

DC link<br />

• Shielded m (ft) 630 (2067) 5) 630 (2067) 5) 1000 (3281) 1000 (3281) 1000 (3281)<br />

Degree of protection IP20 IP20 IP20 IP20 IP20<br />

Dimensions<br />

• Width mm (in) 100 (3.94) 150 (5.91) 200 (7.87) 300 (11.8) 300 (11.8)<br />

•Height mm (in) 380 (15.0) 380 (15.0) 380 (15.0) 380 (15.0) 380 (15.0)<br />

- With fan 6) mm (in) – – – 629 (24.8) 629 (24.8)<br />

- With screwed fitting mm (in) – – – 629 (24.8) 553 (<strong>21</strong>.8) 2)<br />

•Depth<br />

- With internal air cooling mm (in) 270 (10.6) 270 (10.6) 270 (10.6) 270 (10.6) 270 (10.6)<br />

- With external air cooling<br />

on/behind mounting surface<br />

mm (in) 226/66.5<br />

(8.90/2.62)<br />

226/71<br />

(8.90/2.80)<br />

226/92<br />

(8.90/3.62)<br />

226/82<br />

(8.90/3.23)<br />

226/82<br />

(8.90/3.23)<br />

- With cold plate cooling mm (in) 226 (8.90) 226 (8.90) 226 (8.90) 226 (8.90) 226 (8.90)<br />

- With liquid cooling mm (in) – – – – 226 (8.90)<br />

Weight, approx.<br />

• With internal air cooling kg (lb) 7 (15) 10.3 (23) 17 (37.5) 23 (51) 23 (51)<br />

• With external air cooling kg (lb) 8.8 (19) 13.8 (30) 18.5 (41) 27.7 (61) 30.7 (68)<br />

• With cold plate cooling kg (lb) 6.1 (13) 10.2 (22.5) 13.8 (30) 20.3 (45) 20.4 (45)<br />

• With liquid cooling kg (lb) – – – – 23 (51)<br />

1) In the case of cold plate cooling, derating is necessary due to heat transfer to the external heat sink.<br />

2) The coolant connections are located on the lower side of the components. All connection elements can be accessed using an appropriate tool.<br />

Thread type of water connections: Pipe thread ISO 228 G ½ B.<br />

3) Power loss of Active Line Module at rated power including losses of 24 V DC electronic power supply.<br />

4) This value applies to water as coolant; for other coolants, refer to the SINAMICS S120 Manual.<br />

5) Max. cable lengths in conjunction with Active Interface Module and Basic Line Filter (Category C3 in accordance with EN 61800-3).<br />

6) The fan is supplied with the Active Line Module and must be installed before the Active Line Module is commissioned.<br />

7) Nominal HP ratings are provided for ease of assigning components only. The Line Module outputs are dependent on the Motor Module loading and are to be<br />

dimensioned accordingly.<br />

<strong>Siemens</strong> <strong>PM</strong> <strong>21</strong> · <strong>2013</strong><br />