Catalog PM 21 2013 - Siemens Industry, Inc.
Catalog PM 21 2013 - Siemens Industry, Inc.
Catalog PM 21 2013 - Siemens Industry, Inc.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
SINAMICS S120 drive system<br />
Load-side power components<br />
Motor reactors for chassis format<br />
© <strong>Siemens</strong> AG <strong>2013</strong><br />
3<br />
■ Technical specifications (continued)<br />
DC link voltage 510 ... 720 V DC<br />
or line voltage 380 … 480 V 3 AC<br />
Motor reactor (for pulse frequencies of 1.25 kHz to 2.5 kHz)<br />
6SL3000-<br />
2AE36-1AA0<br />
6SL3000-2AE38-4AA0<br />
6SL3000-<br />
2AE41-0AA0<br />
6SL3000-2AE41-4AA0<br />
Rated current A 605 840 840 985 1405 1405<br />
Rated inductance μH 18 13 13 10 5.1 5.1<br />
Power loss kW 0.9 0.84 0.943 1.062 0.9 1.054<br />
Line/load connection<br />
Flat connector<br />
for M12 screw<br />
Flat connector<br />
for M12 screw<br />
Flat connector<br />
for M12 screw<br />
Flat connector<br />
for M12 screw<br />
Flat connector<br />
for M12 screw<br />
(2 ×)<br />
Flat connector<br />
for M12 screw<br />
(2 ×)<br />
PE connection M10 screw M10 screw M10 screw M10 screw M10 screw M10 screw<br />
Max. cable length between<br />
motor reactor and motor<br />
(number of reactors in series) (1) (2) (1) (2) (1) (2) (1) (2) (1) (2) (1) (2)<br />
• Shielded m (ft) 300<br />
(984)<br />
525<br />
(1722)<br />
300<br />
(984)<br />
525<br />
(1722)<br />
300<br />
(984)<br />
525<br />
(1722)<br />
300<br />
(984)<br />
525<br />
(1722)<br />
300<br />
(984)<br />
525<br />
(1722)<br />
300<br />
(984)<br />
525<br />
(1722)<br />
• Unshielded m (ft) 450<br />
(1476)<br />
787<br />
(2582)<br />
450<br />
(1476)<br />
787<br />
(2582)<br />
450<br />
(1476)<br />
787<br />
(2582)<br />
450<br />
(1476)<br />
787<br />
(2582)<br />
450<br />
(1476)<br />
787<br />
(2582)<br />
450<br />
(1476)<br />
787<br />
(2582)<br />
Degree of protection IP00 IP00 IP00 IP00 IP00 IP00<br />
Dimensions<br />
• Width mm (in) 410 (16.1) 410 (16.1) 410 (16.1) 410 (16.1) 460 (18.1) 460 (18.1)<br />
•Height mm (in) 392 (15.4) 392 (15.4) 392 (15.4) 392 (15.4) 392 (15.4) 392 (15.4)<br />
•Depth mm (in) 292 (11.5) 292 (11.5) 292 (11.5) 302 (11.9) 326 (12.8) 326 (12.8)<br />
Weight, approx. kg (lb) 130 (287) 140 (309) 140 (309) 146 (322) 179 (395) 179 (395)<br />
Approvals, according to cURus cURus cURus cURus cURus cURus<br />
Suitable for<br />
Single Motor Module<br />
in chassis format<br />
• Rated current<br />
of the Motor Module<br />
• Type of rating<br />
of the Motor Module<br />
Type<br />
6SL3320-<br />
1TE36-1AA3<br />
6SL3320-<br />
1TE37-5AA3<br />
6SL3320-<br />
1TE38-4AA3<br />
6SL3320-<br />
1TE41-0AA3<br />
6SL3320-<br />
1TE41-2AA3<br />
A 605 745 840 985 1260 1405<br />
6SL3320-<br />
1TE41-4AA3<br />
kW (HP) 315 (500) 400 (600) 450 (700) 560 (800) 710 (1000) 800 (1150)<br />
DC link voltage 675 ... 1035 V DC<br />
or line voltage 500 … 690 V 3 AC<br />
Motor reactor (for pulse frequencies of 1.25 kHz to 2.5 kHz)<br />
6SL3000-2AH31-0AA0 6SL3000-2AH31-5AA0 6SL3000-<br />
2AH31-8AA0<br />
6SL3000-<br />
2AH32-4AA0<br />
Rated current A 100 100 150 150 175 <strong>21</strong>5<br />
Rated inductance μH 160 160 110 110 80 53<br />
Power loss kW 0.257 0.3 0.318 0.335 0.4 0.425<br />
Line/load connection<br />
Flat connector<br />
for M10 screw<br />
Flat connector<br />
for M10 screw<br />
Flat connector<br />
for M10 screw<br />
Flat connector<br />
for M10 screw<br />
Flat connector<br />
for M10 screw<br />
Flat connector<br />
for M10 screw<br />
PE connection M6 screw M6 screw M6 screw M6 screw M6 screw M6 screw<br />
Max. cable length between<br />
motor reactor and motor<br />
(number of reactors in series) (1) (2) (1) (2) (1) (2) (1) (2) (1) (2) (1) (2)<br />
• Shielded m (ft) 300<br />
(984)<br />
525<br />
(1722)<br />
300<br />
(984)<br />
525<br />
(1722)<br />
300<br />
(984)<br />
525<br />
(1722)<br />
300<br />
(984)<br />
525<br />
(1722)<br />
300<br />
(984)<br />
525<br />
(1722)<br />
300<br />
(984)<br />
525<br />
(1722)<br />
• Unshielded m (ft) 450<br />
(1476)<br />
787<br />
(2582)<br />
450<br />
(1476)<br />
787<br />
(2582)<br />
450<br />
(1476)<br />
787<br />
(2582)<br />
450<br />
(1476)<br />
787<br />
(2582)<br />
450<br />
(1476)<br />
787<br />
(2582)<br />
450<br />
(1476)<br />
Degree of protection IP00 IP00 IP00 IP00 IP00 IP00<br />
Dimensions<br />
• Width mm (in) 270 (10.6) 270 (10.6) 270 (10.6) 270 (10.6) 300 (11.8) 300 (11.8)<br />
•Height mm (in) 248 (9.76) 248 (9.76) 248 (9.76) 248 (9.76) 285 (11.2) 285 (11.2)<br />
•Depth mm (in) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) <strong>21</strong>2 (8.35) <strong>21</strong>2 (8.35)<br />
Weight, approx. kg (lb) 25 (55) 25 (55) 25.8 (57) 25.8 (57) 34 (75) 34 (75)<br />
Approvals, according to – – – – – –<br />
Suitable for<br />
Single Motor Module<br />
Type 6SL3320-<br />
1TG28-5AA3<br />
6SL3320-<br />
1TG31-0AA3<br />
6SL3320-<br />
1TG31-2AA3<br />
6SL3320-<br />
1TG31-5AA3<br />
6SL3320-<br />
1TG31-8AA3<br />
6SL3320-<br />
1TG32-2AA3<br />
in chassis format<br />
• Rated current<br />
A 85 100 120 150 175 <strong>21</strong>5<br />
of the Motor Module<br />
• Type of rating<br />
of the Motor Module<br />
kW 75 90 110 132 160 200<br />
787<br />
(2582)<br />
3/204 <strong>Siemens</strong> <strong>PM</strong> <strong>21</strong> · <strong>2013</strong>