© <strong>Siemens</strong> AG <strong>2013</strong><br />

SINAMICS S120 drive system<br />

Motor Modules<br />

Single Motor Modules<br />

in booksize compact format<br />

■ Integration<br />

Single Motor Modules communicate with the Control Unit via DRIVE-CLiQ.<br />

X200<br />

X201<br />

Single Motor Module<br />

DRIVE-CLiQ socket 0<br />

DRIVE-CLiQ socket 1<br />

3<br />

+<br />

M<br />

+<br />

M<br />

24 V DC busbars<br />

DCP<br />

DCN<br />

DCP<br />

DCN<br />

DC link busbars<br />

X<strong>21</strong><br />

1<br />

+Temp<br />

X202<br />

2)<br />

2<br />

-Temp<br />

DRIVE-CLiQ socket 2<br />

3<br />

EP +24 V<br />

X1<br />

E<br />

1)<br />

4<br />

EP M1<br />

M<br />

U2<br />

V2<br />

W2<br />

M<br />

3 ~<br />

X11<br />

LEDs<br />

READY<br />

DC LINK<br />

3)<br />

BR+<br />

BR-<br />

1<br />

2<br />

G_D<strong>21</strong>1_EN_00193<br />

1) Required for Safety.<br />

2) Temperature sensor terminal for motors without DRIVE-CLiQ interface.<br />

3) The braking signal has an integrated overvoltage protection.<br />

An external circuit of the holding brake is not necessary.<br />

Connection example for Single Motor Module in booksize compact format<br />

<strong>Siemens</strong> <strong>PM</strong> <strong>21</strong> · <strong>2013</strong><br />