SINAMICS S120 drive system<br />

Control Units<br />

CU310-2 Control Unit for single-axis drives<br />

■ Integration<br />

© <strong>Siemens</strong> AG <strong>2013</strong><br />

+<br />

3<br />

8)<br />

24 V<br />

ext.<br />

24 V<br />

M<br />

M<br />

X124<br />

+<br />

+<br />

M<br />

M<br />

X<strong>21</strong> PROFIBUS<br />

X150 P1 X150 P2<br />

PROFINET<br />

24 V<br />

M<br />

M<br />

X22<br />

2 3 5<br />

RxD<br />

TxD<br />

M<br />

serial interface<br />

X100<br />

DRIVE-CLiQ socket 0<br />

X23<br />

Encoder interface<br />

ext.<br />

24 V<br />

24 V2 M2<br />

6)<br />

7)<br />

24 V1<br />

Curr. sourcing<br />

Curr. sinking<br />

M1<br />

24 V1<br />

Curr. sourcing<br />

Curr. sourcing<br />

M1<br />

ext.<br />

24 V<br />

X120<br />

1<br />

+Temp 1)<br />

2<br />

-Temp 1)<br />

3 DI 16<br />

24 V1 4 DI 17+<br />

5 DI 17-<br />

6 DI 18<br />

7 DI 19+<br />

M1 8 DI 19-<br />

M1<br />

9<br />

10<br />

11<br />

12<br />

DI 20<br />

DI <strong>21</strong>+<br />

DI <strong>21</strong>-<br />

M1<br />

2)<br />

2)<br />

2)<br />

F-DI 0<br />

F-DI 1<br />

F-DI 2<br />

DI 0<br />

DI 1<br />

DI 2<br />

DI 3<br />

4)<br />

4)<br />

4)<br />

4)<br />

DI 0<br />

DI 1<br />

DI 2<br />

DI 3<br />

M2<br />

M<br />

DI/DO 8<br />

DI/DO 9<br />

M<br />

DI/DO 10<br />

DI/DO 11<br />

M<br />

X1<strong>21</strong><br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

3)<br />

24 V<br />

6)<br />

24 V1<br />

M1<br />

X130<br />

1<br />

2<br />

DI 22+<br />

DI 22-<br />

DI 22<br />

4)<br />

4)<br />

DI/DO 12<br />

DI/DO 13<br />

X131<br />

1<br />

2<br />

24 V<br />

M1<br />

3<br />

4<br />

5<br />

M2<br />

M<br />

M1<br />

24 V1 6 24 V1<br />

F-DO 0<br />

7<br />

8<br />

DO 16+<br />

DO 16-<br />

Memory card<br />

Control Unit<br />

CU310-2<br />

4)<br />

4)<br />

M 3<br />

DI/DO 14 4<br />

DI/DO 15 5<br />

M 6<br />

AI 0+ 7<br />

AI 0- 8<br />

G_D<strong>21</strong>1_EN_00278<br />

5)<br />

± 10 V<br />

6)<br />

1) Motor temperature sensor input must be shielded.<br />

2) Inversion can be parameterized.<br />

3) Jumper open, isolation for digital inputs (DI).<br />

4) High-speed inputs must be shielded.<br />

5) Analog input must be shielded.<br />

6) Safety-related control with current sourcing and current sinking outputs.<br />

7) Safety-related control with two current sourcing outputs.<br />

8) In order to use the digital outputs, an external 24 V power supply must be connected to terminal X124.<br />

Connection example of CU310-2 Control Unit<br />

3/16 <strong>Siemens</strong> <strong>PM</strong> <strong>21</strong> · <strong>2013</strong>