© <strong>Siemens</strong> AG <strong>2013</strong><br />

SINAMICS S120 drive system<br />

Power Modules and line-side components<br />

Air-cooled Power Modules<br />

in blocksize format<br />

■ Technical specifications (continued)<br />

Line voltage<br />

Air-cooled <strong>PM</strong>340 Power Module in blocksize format<br />

380 … 480 V 3 AC 6SL3<strong>21</strong>0-<br />

1SE11-3UA0<br />

6SL3<strong>21</strong>0-<br />

1SE11-7UA0<br />

6SL3<strong>21</strong>0-<br />

1SE12-2UA0<br />

6SL3<strong>21</strong>0-<br />

1SE13-1UA0<br />

6SL3<strong>21</strong>0-<br />

1SE14-1UA0<br />

Output current<br />

• Rated current I rated A 1.3 1.7 2.2 3.1 4.1<br />

• Base-load current I H A 1.1 1.5 1.9 2.7 3.6<br />

• For S6 duty (40 %) I S6 A 1.3 2.0 2.5 3.5 4.5<br />

• I max A 2.6 3.4 4.4 6.2 8.2<br />

Type rating 1)<br />

• Based on I rated kW (HP) 0.37 (0.5) 0.55 (0.75) 0.75 (1) 1.1 (1.5) 1.5 (2)<br />

• Based on I H kW (HP) 0.37 (0.5) 0.55 (0.5) 0.75 (0.75) 1.1 (1) 1.5 (2)<br />

Rated pulse frequency kHz 4 4 4 4 4<br />

Power loss kW 0.10 0.10 0.10 0.11 0.11<br />

Cooling air requirement m 3 /s (ft 3 /s) 0.005 (0.02) 0.005 (0.02) 0.005 (0.02) 0.005 (0.02) 0.005 (0.02)<br />

Sound pressure level L pA dB < 45 < 45 < 45 < 45 < 45<br />

(1 m)<br />

24 V DC power supply A 1.0 1.0 1.0 1.0 1.0<br />

for the Control Unit<br />

Rated input current 2) A 1.3/1.7 1.7/2.2 2.2/2.6 3.1/3.9 4.1/4.8<br />

with/without line reactor<br />

Resistance value<br />

Ω ≥ 390 ≥ 390 ≥ 390 ≥ 390 ≥ 390<br />

of the external braking resistor<br />

Cable length<br />

to braking resistor, max.<br />

m (ft) 15 (49) 15 (49) 15 (49) 15 (49) 15 (49)<br />

Line connection<br />

U1/L1, V1/L2, W1/L3<br />

Screw-type<br />

terminals<br />

Screw-type<br />

terminals<br />

Screw-type<br />

terminals<br />

Screw-type<br />

terminals<br />

Screw-type<br />

terminals<br />

• Conductor cross-section mm 2 1.0 … 2.5 1.0 … 2.5 1.0 … 2.5 1.0 … 2.5 1.0 … 2.5<br />

DC link connection,<br />

connection for braking<br />

resistor<br />

DCP/R1, DCN, R2<br />

Screw-type<br />

terminals<br />

Screw-type<br />

terminals<br />

Screw-type<br />

terminals<br />

Screw-type<br />

terminals<br />

Screw-type<br />

terminals<br />

• Conductor cross-section mm 2 1.0 … 2.5 1.0 … 2.5 1.0 … 2.5 1.0 … 2.5 1.0 … 2.5<br />

Motor connection<br />

U2, V2, W2<br />

Screw-type<br />

terminals<br />

Screw-type<br />

terminals<br />

Screw-type<br />

terminals<br />

Screw-type<br />

terminals<br />

Screw-type<br />

terminals<br />

• Conductor cross-section mm 2 1.0 … 2.5 1.0 … 2.5 1.0 … 2.5 1.0 … 2.5 1.0 … 2.5<br />

PE connection M4 screw M4 screw M4 screw M4 screw M4 screw<br />

Motor cable length 3) , max.<br />

• Shielded m (ft) 50 (164) 50 (164) 50 (164) 50 (164) 50 (164)<br />

• Unshielded m (ft) 75 (246) 75 (246) 75 (246) 75 (246) 75 (246)<br />

Degree of protection IP20 IP20 IP20 IP20 IP20<br />

Dimensions<br />

• Width mm (in) 73 (2.87) 73 (2.87) 73 (2.87) 73 (2.87) 73 (2.87)<br />

•Height mm (in) 173 (6.81) 173 (6.81) 173 (6.81) 173 (6.81) 173 (6.81)<br />

•Depth<br />

-<strong>PM</strong>340 mm (in) 145 (5.71) 145 (5.71) 145 (5.71) 145 (5.71) 145 (5.71)<br />

- <strong>PM</strong>340 with CU310-2/D410-2 mm (in) 234.6 (9.24) 234.6 (9.24) 234.6 (9.24) 234.6 (9.24) 234.6 (9.24)<br />

- <strong>PM</strong>340 with CUA31/CUA32 mm (in) 175.3 (6.90) 175.3 (6.90) 175.3 (6.90) 175.3 (6.90) 175.3 (6.90)<br />

Frame size FSA FSA FSA FSA FSA<br />

Weight, approx. kg (lb) 1.2 (3) 1.2 (3) 1.2 (3) 1.2 (3) 1.2 (3)<br />

3<br />

1) Nominal HP based on asynchronous (induction) motors and 460 V 3 AC. For specific sizing select drive based on motor nameplate current and overload.<br />

2) The input current depends on the motor load and line impedance.<br />

The input currents apply for rated power loading (based on I rated ) for a line impedance corresponding to u k = 1 %.<br />

3) Max. motor cable length 25 m (82 ft) (shielded) for <strong>PM</strong>340 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.<br />

<strong>Siemens</strong> <strong>PM</strong> <strong>21</strong> · <strong>2013</strong><br />

3/33