4. SYSTEM DESCRIPTION<br />

4.8 Verification <strong>of</strong> Model<br />

All variables in the model have been assigned units. EES has a feature<br />

to check units automatically. This has been carried out <strong>and</strong> no unit<br />

problems were found 15 .<br />

4.8.1 Energy balance<br />

The conservation <strong>of</strong> energy must be fulfilled for all energy systems. In<br />

order to verify the model, an energy balance around the entire system<br />

has been made:<br />

EB tot =∆Ḣ i − ∆Ḣ W GHE X 3,g ,o − Ḣ air,i − Ḣ air,o + ˙Q Chill,EV AP (4.16)<br />

− ˙Q HW + Ḣ w,add +Ẇ BLOW +Ẇ F AN +Ẇ PU MP1<br />

+Ẇ PU MP2 −Ẇ SOFC = 0<br />

where ∆Ḣ W GHE X 3,g ,o is the enthalpy flow <strong>of</strong> discharged exhaust gas,<br />

Ḣ air,i <strong>and</strong> Ḣ air,o is the enthalpy flow <strong>of</strong> the air into the cooling tower<br />

<strong>and</strong> out <strong>of</strong> it, <strong>and</strong> Ḣ w,add is the enthalpy <strong>of</strong> the fresh water added to the<br />

cooling tower.<br />

4.8.2 Check <strong>of</strong> heat exchangers<br />

Most <strong>of</strong> the heat exchangers are defined by a Closest Approach Temperature<br />

Difference. This can however introduce an error if the chosen parameter<br />

for the approach temperature difference is not the closest one - in that<br />

case the real closest approach temperature can then become negative<br />

(whereby ɛ exceeds one).<br />

To avoid this error a variable ”ɛ M AX ” has been introduced. It simply<br />

finds the largest effectiveness <strong>of</strong> all the heat exchangers in the system.<br />

This way it is not necessary to monitor the effectiveness <strong>of</strong> all the heat<br />

exchangers during simulation as long as ɛ M AX does not exceed 1,0.<br />

15 Due to a bug in the external function ”CP_LiBrH2O.LIB” (the unit <strong>of</strong> c p is set<br />

to kJ<br />

kg <strong>and</strong> not kJ<br />

kgK<br />

), so the unit check feature finds 15 unit problems - all related to<br />

CP_LiBrH2O.LIB. These have been checked manually <strong>and</strong> no error was found.<br />