C. EES<br />

C.4.5 ˙Qloss for absorption subsystem<br />

Variable+Uncertainty Partial Derivative % <strong>of</strong> Uncertainty<br />

COP ABS;f uel = 0,4556 ± 0,03209[-]<br />

˙Qloss;Bur n = 0 ± 1[kW ] ∂COP ABS;f uel /∂ ˙Qloss;Bur n = −0,01392 18,82 %<br />

˙Qloss;DES1 = 0 ± 1[kW ] ∂COP ABS;f uel /∂ ˙Qloss;DES1 = −0,007894 6,05 %<br />

˙Qloss;DES2 = 0 ± 1[kW ] ∂COP ABS;f uel /∂ ˙Qloss;DES2 = −0,014 19,03 %<br />

˙Qloss;PR = 0 ± 1[kW ] ∂COP ABS;f uel /∂ ˙Qloss;PR = −0,01403 19,11 %<br />

˙Qloss;SHE X 1 = 0 ± 1[kW ] ∂COP ABS;f uel /∂ ˙Qloss;SHE X 1 = −0,008557 7,11 %<br />

˙Qloss;SHE X 2 = 0 ± 1[kW ] ∂COP ABS;f uel /∂ ˙Qloss;SHE X 2 = −0,01406 19,21 %<br />

˙Qloss;SOFC = 0 ± 1[kW ] ∂COP ABS;f uel /∂ ˙Qloss;SOFC = −0,01049 10,68 %<br />

ηHW = 0,07184 ± 0,003323[-]<br />

˙Qloss;Bur n = 0 ± 1[kW ] ∂ηHW /∂ ˙Qloss;Bur n = −2,882E − 10 0,00 %<br />

˙Qloss;DES1 = 0 ± 1[kW ] ∂ηHW /∂ ˙Qloss;DES1 = −1,016E − 14 0,00 %<br />

˙Qloss;DES2 = 0 ± 1[kW ] ∂ηHW /∂ ˙Qloss;DES2 = 4,574E − 14 0,00 %<br />

˙Qloss;PR = 0 ± 1[kW ] ∂ηHW /∂ ˙Qloss;PR = −1,321E − 14 0,00 %<br />

˙Qloss;SHE X 1 = 0 ± 1[kW ] ∂ηHW /∂ ˙Qloss;SHE X 1 = 3,795E − 14 0,00 %<br />

˙Qloss;SHE X 2 = 0 ± 1[kW ] ∂ηHW /∂ ˙Qloss;SHE X 2 = −2,473E − 14 0,00 %<br />

˙Qloss;SOFC = 0 ± 1[kW ] ∂ηHW /∂ ˙Qloss;SOFC = −0,003323 100,00 %<br />

ηsys;el;net = 0,516 ± 0,003461[-]<br />

˙Qloss;Bur n = 0 ± 1[kW ] ∂ηsys;el ;net /∂ ˙Qloss;Bur n = 0,0006088 3,09 %<br />

˙Qloss;DES1 = 0 ± 1[kW ] ∂ηsys;el ;net /∂ ˙Qloss;DES1 = 0,0004529 1,71 %<br />

˙Qloss;DES2 = 0 ± 1[kW ] ∂ηsys;el ;net /∂ ˙Qloss;DES2 = 0,0006089 3,09 %<br />

˙Qloss;PR = 0 ± 1[kW ] ∂ηsys;el ;net /∂ ˙Qloss;PR = 0,0006089 3,09 %<br />

˙Qloss;SHE X 1 = 0 ± 1[kW ] ∂ηsys;el ;net /∂ ˙Qloss;SHE X 1 = 0,0004679 1,83 %<br />

˙Qloss;SHE X 2 = 0 ± 1[kW ] ∂ηsys;el ;net /∂ ˙Qloss;SHE X 2 = 0,0006089 3,09 %<br />

˙Qloss;SOFC = 0 ± 1[kW ] ∂ηsys;el ;net /∂ ˙Qloss;SOFC = 0,003174 84,08 %<br />

268