2.3. Micro Combined Heat <strong>and</strong> Power (µCHP)<br />

2.3 Micro Combined Heat <strong>and</strong> Power (µCHP)<br />

2.3.1 Micro CHP - Air condition<br />

If a SOFC is installed in private homes to generate electrical power,<br />

the waste heat can be utilized for domestic hot water as well as space<br />

heating. The space heating, however, is not so relevant during summer<br />

in hot climates, although hot water is still necessary for showering etc.<br />

Many places (e.g. the US or in most asian countries) air conditioners are<br />

employed during most <strong>of</strong> the summer. So it would be beneficial if the<br />

excessive heat from the SOFC could be used in an absorption cooling<br />

unit to create air conditioning.<br />

By contacting the majority <strong>of</strong> the producers <strong>of</strong> ABS units it was<br />

discovered that the smallest available heat driven air conditioning unit<br />

had a cooling power <strong>of</strong> 4kW, which is in the right range for cooling a<br />

one family house 2 . But the heat dem<strong>and</strong> <strong>of</strong> the absorption unit was<br />

12.5kW 3 which was far more than the maximum approximately 1kW<br />

heat which would in average be supplied by the SOFC for a 1kW <strong>of</strong><br />

electricity production 4 .<br />

Of course the absorption cooling unit could be run at part load, but<br />

the low COP combined with fact that some <strong>of</strong> the waste heat was to<br />

be used to heat up the hot water, <strong>and</strong> that some part <strong>of</strong> the waste heat<br />

can not be extracted due to heat exchanger efficiency below 1, made the<br />

absorption unit a very bad match for the SOFC. Furthermore the small<br />

absorption chillers are fairly expensive per kW, so they have to have a lot<br />

<strong>of</strong> full load hours in order to make for a reasonable pay back time.<br />

Conclusion<br />

This all meant that there seems not to be a potential for using an<br />

absorption air conditioning unit together with SOFCs in private homes.<br />

2 Assuming a well insulated house or that the climate is not too hot.<br />

3 the small 4kW absorption unit had a COP <strong>of</strong> only 0,4 whereas most <strong>of</strong> the larger<br />

single cycle units experienced COPs <strong>of</strong> around 0,7<br />

4 assuming an electrical efficiency <strong>of</strong> the SOFC <strong>of</strong> approximately 0,5 <strong>and</strong> an expected<br />

electrical power consumption <strong>of</strong> a single family house <strong>of</strong> 1kW [32]<br />