6.2. High humidity climate<br />

Figure 6.4: A: The relative humidity is φ = 0,9. B: The desorber temperature is either kept<br />

at 150 ◦ C (moderate humidity) or varied (VAR.)(very high humidity). The water consumption<br />

corresponds to a <strong>fuel</strong> input <strong>of</strong> 100kW.<br />

It might be possible to design a desorber which is capable to operate<br />

at this high temperature by means <strong>of</strong> more corrosion resistant materials,<br />

but it is out <strong>of</strong> the scope <strong>of</strong> this report to investigate this further.<br />

The above results show that it is more complicated to implement a<br />

system <strong>of</strong> SOFC integrated with absorption air conditioning in a climate<br />

like the one in Bangkok than the one in the Seychelles. This should be<br />

taken into account when potentially new markets are considered.<br />