4.9. Validation <strong>of</strong> Model<br />

4.9 Validation <strong>of</strong> Model<br />

During the development <strong>of</strong> the model, the output (results) has been<br />

compared to other models as well as measured data. Rules <strong>of</strong> thumb<br />

have also been taken into account. In some cases additional variables<br />

have been introduced in order to validate the model <strong>and</strong> will be<br />

described in the following.<br />

4.9.1 SOFC<br />

In the st<strong>and</strong>ard parameter configuration the increase <strong>of</strong> the temperature<br />

from the inlet to the outlet <strong>of</strong> the <strong>fuel</strong> cell (∆T SOFC ) is 90 ◦ C. The <strong>fuel</strong><br />

utilization factor U f is 0,7 <strong>and</strong> the current density isi d = 3000 A . The<br />

m 2<br />

fraction <strong>of</strong> reforming in the pre reformer (F R) is 0,14. The air utilization<br />

factor (U air ) which is dependent on ∆T SOFC , U f <strong>and</strong> F R is calculated to<br />

0,16 which is quite close to that <strong>of</strong> the TOFC models [25].<br />

Recycling<br />

The fraction <strong>of</strong> anode recycling α SPG1 is 0,62. This deviates less than<br />

5% from an equivalent SOFC system modeled by TOFC. And the gas<br />

composition at the SOFC anode outlet matches the TOFC model.<br />

Blower power<br />

A rule <strong>of</strong> thumb says that the blower consumes 10% <strong>of</strong> the produced<br />

power [25]. Ẇ Blower is 5,5kW which corresponds to 10% <strong>of</strong> Ẇ SOFC ,SOLO<br />

(see definition in equation 4.6 <strong>and</strong> 4.7 page 98), while the TOFC models<br />

the fraction is in the range <strong>of</strong> only 5-8% <strong>of</strong> the net power.<br />

Since the SOFC system in this project is integrated with an absorption<br />

cooling unit, more heat exchangers are applied <strong>and</strong> hence it is expected<br />

that the total pressure loss <strong>of</strong> the exhaust gases must be higher. Taking<br />

this into account the blower power consumption seems to be reasonable.<br />