The structures have the necessary bearing capacity to withstand specific normative and<br />

extreme snow loads.<br />

4.3.4.3 Extreme temperatures<br />

High temperatures, to the maximum measured <strong>for</strong> the area <strong>of</strong> <strong>Kozloduy</strong> <strong>NPP</strong> do not bear<br />

mechanical loads on the structures <strong>of</strong> DSFS.<br />

In the given design basis extreme values <strong>of</strong> temperatures do not lead to failure to the DSFS<br />

safety functions.<br />

In the operational history <strong>of</strong> the plant there are no events and accident initiated by extremely<br />

low or extremely high temperatures.<br />

4.3.5 Outdoor Switchyard<br />

4.3.5.1 Extreme winds<br />

The structure if OSY building is provided <strong>for</strong> bearing capacity, robustness and de<strong>for</strong>mability<br />

according to the requirements <strong>of</strong> the applicable normative documents.<br />

4.3.5.2 Extreme snowfalls<br />

The calculated value <strong>of</strong> snow load (2,52 kN/m2) is by 50% greater than the normative value<br />

(1.68 kN/m2) and 57% greater than the extreme values <strong>of</strong> snow loads (1.6 kN/m2).<br />

The structure has reliable stiffness and may withstand normative and extreme snow loads.<br />

4.3.5.3 Extreme temperatures<br />

Extreme temperatures are within the design basis <strong>of</strong> OSY SSCs.<br />

High temperatures do not apply mechanical loads <strong>for</strong> the structures and buildings.<br />

4.3.5.4 Freezing<br />

The freezing in the region <strong>of</strong> <strong>Kozloduy</strong> is a relatively seldom phenomena.<br />

The current operational experience since 1971 shows that <strong>for</strong> OSY there is no case <strong>of</strong><br />

rupture <strong>of</strong> power lines <strong>for</strong> <strong>of</strong>f-site power supply or failure to <strong>of</strong>f-site power supply due to freezing.<br />

Considering the large number <strong>of</strong> connections in various directions <strong>of</strong> <strong>Kozloduy</strong> <strong>NPP</strong>, breaking <strong>of</strong> all<br />

lines simultaneously is unlikely.<br />

4.4 CONCLUSION FOR IMPACT OF THE EXTREME EXTERNAL EVENTS<br />

ON THE BUILDINGS AND FACILITIES OF KOZLODUY <strong>NPP</strong> SITE<br />

Facilities at the site, except ASSGEM, FPS 2 and DSFS, were designed be<strong>for</strong>e early 80s <strong>of</strong><br />

the 20th century, according to the regulations and standards applicable at the time. Changes in<br />

136/202