17.04.2015 Views

Summary Report for Conduct of Kozloduy NPP Stress Tests

Summary Report for Conduct of Kozloduy NPP Stress Tests

Summary Report for Conduct of Kozloduy NPP Stress Tests

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

“<strong>Kozloduy</strong> <strong>NPP</strong>” PLC<br />

SUMMARY REPORT<br />

<strong>for</strong> <strong>Conduct</strong> <strong>of</strong> <strong>Kozloduy</strong> <strong>NPP</strong><br />

<strong>Stress</strong> <strong>Tests</strong><br />

· Turbine hall and electric building fire alarm and fire extinguishing systems;<br />

· Auxiliary building-3 fire alarm and fire extinguishing systems.<br />

2.5.3.4.3 Measures <strong>for</strong> protection against explosions<br />

According to the analysis [87] in the report assessment <strong>of</strong> the safety impact and proposals<br />

are made <strong>for</strong> organizational measures to prevent from and to reduce the consequences <strong>of</strong> explosion<br />

on petrol station owned by <strong>Kozloduy</strong> <strong>NPP</strong> located in the area <strong>of</strong> Garage No. 2: the total amount <strong>of</strong><br />

petrol in the petrol station shall not exceed three tons.<br />

In pursuance <strong>of</strong> this recommendation analysis and assessment <strong>of</strong> the impact from potential<br />

explosion <strong>of</strong> petrol occurred in the plant owned petrol station on the neighbouring facilities and<br />

structures in the area <strong>of</strong> <strong>Kozloduy</strong> <strong>NPP</strong> have been developed, [88]. The results <strong>of</strong> the study [88]<br />

demonstrate that at potential explosion <strong>of</strong> petrol the Nis and safety systems elements will not be<br />

affected.<br />

2.6 PROVISIONS MADE FOR PROTECTION AT RLE OF SFS<br />

2.6.1 Systems, structures and components (SSCs) required <strong>for</strong> maintaining SFS in safe state<br />

According to the recommendations [3] the stress tests are per<strong>for</strong>med based on the available<br />

and approved by <strong>Kozloduy</strong> <strong>NPP</strong> instructions, procedures, technical specifications, SAR, technical<br />

decisions and their substantiations, results <strong>of</strong> studies and reviews.<br />

Analysis [44] was per<strong>for</strong>med covering all operational states taking into account the most<br />

unfavourable conditions (boundary conditions <strong>of</strong> operation) according to [26].<br />

To cope with different accident scenarios SSCs (elements) are summarized according to lists<br />

mentioned in item 2.1.1.4. <strong>of</strong> [85]:<br />

· Emergency DG <strong>of</strong> SFS;<br />

· Mobile DG;<br />

· Interlocking <strong>of</strong> the refuelling machine in SFS by industrial seismic protection system<br />

(III and IV unit);<br />

· Level gauges in the rooms at emergency flooding <strong>of</strong> elevation -7.20m;<br />

· Fire alarm system in SFS;<br />

· Fire tubes drying from elevation 0.00m to the ro<strong>of</strong> <strong>of</strong> building in SFS;<br />

· Compartments <strong>for</strong> SNF storage (civil structure, pipelines and valves <strong>for</strong> leak<br />

control);<br />

· SFS building;<br />

· Bridge crane 160/32/8t (incl. load carrying structures <strong>for</strong> container handling);<br />

· Crane 16 t (incl. load carrying structures <strong>for</strong> SNF handling)<br />

· SFS DG building.<br />

79/202