17.04.2015 Views

Summary Report for Conduct of Kozloduy NPP Stress Tests

Summary Report for Conduct of Kozloduy NPP Stress Tests

Summary Report for Conduct of Kozloduy NPP Stress Tests

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

“<strong>Kozloduy</strong> <strong>NPP</strong>” PLC<br />

SUMMARY REPORT<br />

<strong>for</strong> <strong>Conduct</strong> <strong>of</strong> <strong>Kozloduy</strong> <strong>NPP</strong><br />

<strong>Stress</strong> <strong>Tests</strong><br />

· protocols <strong>of</strong> SSCs periodic inspections are produced. The results <strong>of</strong> SSCs inspection<br />

according to programme [82] from 30.06.2011 are provided in the completion certificate<br />

[79].<br />

· automatic actions – emergency tripping system at an earthquake [80], item 7.2.4.2.3<br />

[7],[8].<br />

· automatic plant in<strong>for</strong>mation systems is established and integrated with similar<br />

national system conducting continuous radiation monitoring within 3 km zone.<br />

· other scheduled measures to prevent, recover from and restriction <strong>of</strong> accident<br />

consequences.<br />

Following the accident in Fukushima Detailed programme was developed <strong>for</strong> review and<br />

assessment <strong>of</strong> <strong>Kozloduy</strong> <strong>NPP</strong> Co. preparedness <strong>for</strong> management and reduction <strong>of</strong> the consequences<br />

<strong>of</strong> beyond design basis accidents, external and internal impacts [84]. The results <strong>of</strong> the current work<br />

under the programme are summarized in the preliminary report [85].<br />

According to item 2.4.2 [85] the number <strong>of</strong> portable submersible pumps in Power<br />

Generation 2 should be optimized, considering more adequate response at internal; floodings.<br />

Efficient and additional measures were proposed considering enhancement <strong>of</strong> protection at external<br />

and internal impacts (Appendix No. 1, [85]), item 2.4.2 [85].<br />

Measures have been taken <strong>for</strong> development and updating <strong>of</strong> the emergency procedures <strong>for</strong><br />

OSY personnel actions at earthquake, flooding, fire and explosion in departments, where needed,<br />

item 2.8.2 [85].<br />

According to the in<strong>for</strong>mation <strong>of</strong> item 2.9.2 [85] the emergency crew capability to per<strong>for</strong>m<br />

the emergency plan and its procedures was tested realistically in an exercise <strong>for</strong> accident with<br />

earthquake and flooding. The persons responsible from the emergency activities management group<br />

according to the emergency procedure are familiarized with the procedure and properly follow it.<br />

2.5.3 Assessment <strong>of</strong> indirect effects <strong>of</strong> the earthquake<br />

2.5.3.1 Assessment <strong>of</strong> potential failures <strong>of</strong> SSCs not seismically qualified that can<br />

compromise heat removal to the ultimate heat sink by mechanical impact or by<br />

internal flooding<br />

Measures are provided to ensure that at destruction <strong>of</strong> elements with lower seismic class will<br />

not damage the SSCs required <strong>for</strong> nuclear installation shutdown and maintaining in safe shutdown<br />

mode.<br />

In this review general plant systems not seismically classified but important <strong>for</strong> coping with<br />

secondary post-earthquake effects are identified and analyzed. Measures taken to preserve their<br />

functionality during and after the earthquake are discussed.<br />

Within the framework <strong>of</strong> Modernization Programme [69] and [70] the following measures to<br />

prevent from seismically induced interactions have been analyzed and implemented:<br />

75/202