“<strong>Kozloduy</strong> <strong>NPP</strong>” PLC<br />

SUMMARY REPORT<br />

<strong>for</strong> <strong>Conduct</strong> <strong>of</strong> <strong>Kozloduy</strong> <strong>NPP</strong><br />

<strong>Stress</strong> <strong>Tests</strong><br />

· notification;<br />

· collection <strong>of</strong> the emergency team at the workplace according to Emergency Plan;<br />

review <strong>of</strong> the feasibility <strong>of</strong> various emergency plans.<br />

6.1.2 Possibility <strong>for</strong> use <strong>of</strong> existing equipment<br />

6.1.2.1 Measures ensuring usage <strong>of</strong> mobile devices (availability <strong>of</strong> such devices, time<br />

required <strong>for</strong> their delivery to the site and putting into operation)<br />

Mobile diesel-generator (MDG) is one <strong>of</strong> measures on design modernization intended to<br />

improve safety and has the purpose <strong>of</strong> redundancy <strong>of</strong> diesel-generators (DG) and providing <strong>for</strong><br />

emergency power supply to "reliable power supply" busbars at common-cause failures in<br />

“<strong>Kozloduy</strong> <strong>NPP</strong>” PLC.<br />

Procedure has been developed on transportation and actuation <strong>of</strong> MDG to the busbars in<br />

premises <strong>of</strong> the pumps <strong>of</strong> steam generators emergency make-up system (SG EMS). The established<br />

success criteria are the time from conditioning <strong>of</strong> alarm on complete loss <strong>of</strong> power supply to the<br />

pump actuation less than 2 hours. Meeting the criteria is confirmed in the observation sheet <strong>of</strong> the<br />

emergency response exercise.<br />

Total reserve <strong>of</strong> fuel and oil <strong>of</strong> MDG ensures its uninterrupted operation at nominal power<br />

during 21 hours and 40 minutes. To energize only the pump <strong>of</strong> the system <strong>for</strong> alternative make-up<br />

<strong>of</strong> the SG, the reserve is sufficient <strong>for</strong> 60 hours.<br />

6.1.2.2 Insurance and management <strong>of</strong> supply (fuel <strong>for</strong> diesel generators, water, etc.)<br />

On the maintained reserves <strong>of</strong> fuel and oil in accordance with normative requirements,<br />

emergency instructions and technical specification in <strong>Kozloduy</strong> <strong>NPP</strong>” ЕАД it is calculated that:<br />

· For units 5 and 6<br />

- Emergency DGs - at operation <strong>of</strong> two emergency DGs (one per unit) total<br />

reserve <strong>of</strong> fuel and oil <strong>of</strong> emergency DGs is sufficient <strong>for</strong> more than 38 days.<br />

- Accumulator batteries (AB) – see par.5.1.1.2.2.<br />

Total reserve <strong>of</strong> fuel and oil <strong>of</strong> additional DGs ensures uninterrupted operation <strong>of</strong> each <strong>of</strong><br />

them <strong>for</strong> more than 4 days.<br />

· For units 3 and 4<br />

- Emergency DGs <strong>of</strong> units 3 and 4 - fuel and oil reserves <strong>for</strong> emergency DGs<br />

ensure their uninterrupted operation <strong>for</strong> more than 4 days.<br />

- Emergency DGs <strong>of</strong> additional system <strong>for</strong> SG emergency make-up<br />

(ASSGEM) - fuel and oil reserves <strong>for</strong> emergency DGs <strong>of</strong> ASSGEM ensure<br />

their uninterrupted operation during 5 days.<br />