In emergencies, when implementation <strong>of</strong> lifesaving activities are required the limit <strong>of</strong> 100<br />

mSv may be exceeded. For example, actions to prevent core damage. In case <strong>of</strong> emergency<br />

activities involving very high risk, they are per<strong>for</strong>med by volunteers from the emergency personnel<br />

<strong>of</strong> the emergency teams. Furthermore, the head <strong>of</strong> the enterprise is obliged to submit to the Minister<br />

<strong>of</strong> Health and the Chairman <strong>of</strong> the NRA the statement accompanied by a list <strong>of</strong> staff who per<strong>for</strong>ms<br />

the operations, their written consent, time and place <strong>of</strong> operations, the opinion <strong>of</strong> the health or other<br />

medical establishment and any other in<strong>for</strong>mation about the circumstances and the measures taken.<br />

For the work <strong>of</strong> emergency personnel <strong>of</strong> the MCR (ECR) and AMC the design solutions<br />

provide habitability in the event <strong>of</strong> a radiological or nuclear accident. These solutions ensure<br />

protection against ionizing radiation, isolation from the environment, air purification from<br />

radioactive purification higher than the external atmospheric pressure, air-conditioning, etc. to<br />

ensure long-term safe stay <strong>of</strong> the personnel.<br />

6.1.3.2 Factors which can prevent management <strong>of</strong> accident <strong>of</strong> units 3 and 4<br />

6.1.3.2.1 Impact on accessibility and habitability <strong>of</strong> the MCR and SCR, measures to prevent or<br />

control the situation<br />

Control and management <strong>of</strong> the technological processes is provided by two main control<br />

rooms (one per each unit). in the technical design separated layout is adopted <strong>of</strong> the main control<br />

rooms which ensure:<br />

· high fire safety <strong>of</strong> the rooms;<br />

· higher reliability in control <strong>of</strong> each unit;<br />

· possibility <strong>of</strong> better cable lying.<br />

Besides design envisions two Standby control rooms (SCR), one per each unit, at which the<br />

units can be shut down in case <strong>of</strong> accident situation at the main control rooms.<br />

<strong>of</strong> the unit.<br />

At the MCR control is envisioned <strong>of</strong> all the main and auxiliary mechanisms and components<br />

At the MCR control is per<strong>for</strong>med <strong>for</strong> operating auxiliaries trans<strong>for</strong>mers 15,75/6,3 kV,<br />

switchgears 6 kV with standby power supply to 6 kV busbars, unit operating and standby<br />

trans<strong>for</strong>mers 6/0,4 kV, elements <strong>of</strong> the grid <strong>for</strong> reliable power supply to the units.<br />

At the MCR the following communications are provided:<br />

· two-way loudspeaking communication <strong>of</strong> duty operator and the shift <strong>of</strong> the operating<br />

personnel;<br />

· command loudspeaker and alarm in the main production premises and in area <strong>of</strong> the<br />

power plant.<br />

At the MCRs <strong>of</strong> the units conditioning systems are mounted <strong>for</strong> maintaining required<br />

conditions <strong>for</strong> uninterrupted work <strong>of</strong> the operators. This is combined with maintaining and setting at<br />

the MCR <strong>of</strong> the so called “working” are <strong>for</strong> the MCR operators.<br />