17.04.2015 Views

Summary Report for Conduct of Kozloduy NPP Stress Tests

Summary Report for Conduct of Kozloduy NPP Stress Tests

Summary Report for Conduct of Kozloduy NPP Stress Tests

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

“<strong>Kozloduy</strong> <strong>NPP</strong>” PLC<br />

SUMMARY REPORT<br />

<strong>for</strong> <strong>Conduct</strong> <strong>of</strong> <strong>Kozloduy</strong> <strong>NPP</strong><br />

<strong>Stress</strong> <strong>Tests</strong><br />

· Medium pressure emergency boron injection system;<br />

· Emergency and normal core cooldown system;<br />

· Passive emergency core cooldown system;<br />

· Primary circuit overpressure protection;<br />

· Secondary circuit overpressure protection;<br />

· Primary circuit emergency gas removal system;<br />

· SG emergency makeup water supply system;<br />

· Containment;<br />

· Spray system;<br />

· Pressure reduction filtering system;<br />

· Hydrogen concentration control and reduction system;<br />

· Essential components service water supply system;<br />

· Supporting ventilation systems;<br />

2.5.1.2.1.2 Reactor<br />

The systems and components classification is per<strong>for</strong>med in the framework <strong>of</strong> modernization<br />

<strong>of</strong> Units 5 and 6 <strong>of</strong> <strong>Kozloduy</strong> <strong>NPP</strong>. The reactor and the internals has been originally designed<br />

considering seismic impact <strong>of</strong> 9 points by MSK-64 scale, item 3.13.4 [7],[8], item 6.3.3 [67].<br />

According to item 6.3.3 [67] these requirements are specified in the Terms <strong>of</strong> Reference (ToR) and<br />

confirmed. Item 4.7 [7],[8] summarizes the actions per<strong>for</strong>med <strong>for</strong> the reactor modernization with<br />

regard to the Modernization Programme <strong>of</strong> Units 5 and 6. The equipment seismic qualification has<br />

been reviewed in the framework <strong>of</strong> the modernization programme [7],[8] and [67].<br />

2.5.1.2.1.3 Reactor building major equipment<br />

The major equipment in the reactor building has been designed considering the seismic<br />

impact loads from 9 points by MSK-643 scale [7] and [8]. Item 5.5 [7],[8] summarizes the actions<br />

completed <strong>for</strong> modernization <strong>of</strong> the primary circuit and related systems with regard to the<br />

modernization programme <strong>of</strong> Units 5 and 6.<br />

Under the modernization programme analysis <strong>of</strong> the behaviour and calculation <strong>of</strong> the<br />

seismic resistance <strong>of</strong> the major equipment and the safety systems equipment was per<strong>for</strong>med and<br />

proposals developed <strong>for</strong> required rein<strong>for</strong>cements, item 6.3.3 [67], item 3.13.4 [7],[8].<br />

The seismic qualification <strong>of</strong> the pipelines, equipment and fixing elements <strong>of</strong> the primary<br />

circuit has been reviewed in a number <strong>of</strong> measures under the modernization programme with the<br />

results are summarized considering the new seismic requirements <strong>for</strong> the site. Qualification <strong>of</strong> the<br />

following primary circuit equipment was confirmed:<br />

· Main circulation lines;<br />

· Steam generators;<br />

· Reactor coolant pumps.<br />