SUMMARY REPORT<br />

<strong>for</strong> <strong>Conduct</strong> <strong>of</strong> <strong>Kozloduy</strong> <strong>NPP</strong><br />

<strong>Stress</strong> <strong>Tests</strong><br />

2.7.1.2 Seismic design basis <strong>for</strong> crane 145 t in DSFS building<br />

Similarly to the building, the crane was also evaluated <strong>for</strong> the following adverse<br />

combinations <strong>of</strong> load conditions:<br />

· OBE (SL1 from 0,1 g) with operating crane 145 t<br />

· DBE (SL2 from 0,2 g) with standby crane 145 t.<br />

Both the building and the crane are designed <strong>for</strong> OBE and DBE without destruction <strong>of</strong> the<br />

structures or load falling.<br />

2.7.1.3 Seismic design basis <strong>for</strong> other process equipment<br />

Clamping devices (hook and sleepers) and contact devices are evaluated only <strong>for</strong> design<br />

basis earthquake (SL1 from 0,1 g) with the operating crane in the storage area, including load from<br />

own weight, fixed loads and impulse loads.<br />

The protective door is estimated <strong>for</strong> DBE (SL1 from 0,1 g) at any position <strong>of</strong> the door, and<br />

<strong>for</strong> DBE (SL2 from 0,2 g) at the closed position <strong>of</strong> the door.<br />

2.7.1.4 Seismic design basis <strong>for</strong> containers CONSTOR® 440/84<br />

Stability <strong>of</strong> the containers against inversion at seismic loads <strong>for</strong> design basis earthquake<br />

(SL1 from 0,1 g) and <strong>for</strong> safe shutdown earthquake (SL2 from 0,2 g) was confirmed.<br />

2.7.2 The main operational measures to maintain DSFS in safe condition after earthquake<br />

DSFS has fire alarm system ensuring local annunciation and the annunciation in the<br />

continuously functioning centre with personnel notifying the site fire fighting service. There is<br />

proper access <strong>of</strong> the fire vehicles to DSFS and corridor between DSFS and SFS. The main<br />

operational measures will be updated and described in the Final Safety Analysis <strong>Report</strong>. This will<br />

be a part <strong>of</strong> the documentation required <strong>for</strong> issuance <strong>of</strong> licence <strong>of</strong> DSFS.<br />

2.7.3 Assessment <strong>of</strong> indirect effects <strong>of</strong> the earthquake<br />

The existing facilities <strong>of</strong> <strong>Kozloduy</strong> <strong>NPP</strong> site that may impact on the DSFS after a seismic<br />

event are SFS and AB-2 chimney.<br />

It is concluded that the DSFS site will not have adverse impact from other facilities on<br />

<strong>Kozloduy</strong> <strong>NPP</strong> site at an earthquake.<br />

2.7.3.1 Assessment <strong>of</strong> potential failures to SSCs not seismically qualified that may<br />

compromise safety and robustness <strong>of</strong> the containers through mechanical interaction<br />

or through internal floodings<br />

This scenario considers the consequences at container blocking with debris that could result<br />

from extreme external initiating events, such as an earthquake, explosion <strong>of</strong> gas or aircraft crash.<br />