Technologies and Costs for Removal of Arsenic From Drinking Water

Technologies and Costs for Removal of Arsenic From Drinking Water

Technologies and Costs for Removal of Arsenic From Drinking Water

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

# Minimally skilled labor - $14.50 per hour (population less than 3,300 individuals).# Skilled labor - $28.00 per hour (population greater than 3,300 individuals).# Life <strong>of</strong> unit - 5 years (POU), 10 years (POE).# Duration <strong>of</strong> cost study - 10 years (there<strong>for</strong>e, two POU devices per household).# Cost <strong>of</strong> water meter <strong>and</strong> automatic shut-<strong>of</strong>f valve included.# No shipping <strong>and</strong> h<strong>and</strong>ling costs required.# Volume discount schedule - retail <strong>for</strong> single unit, 10 percent discount <strong>for</strong> 10 or moreunits, vendor retains 30 percent pr<strong>of</strong>it on more than 100 units.# Installation time - 1 hour unskilled labor (POU), 3 hours, skilled labor (POE).# O&M costs include maintenance, replacement <strong>of</strong> pre-filters <strong>and</strong> resin cartridges,laboratory sampling <strong>and</strong> analysis, <strong>and</strong> administrative costs.<strong>Arsenic</strong> removal by AA is very sensitive to pH, <strong>and</strong> finished water pH typically will be higherthan the optimal required <strong>for</strong> AA. A finished water pH <strong>for</strong> many systems would be in the range <strong>of</strong> pH7 to pH 8. Using data on activated alumina run length <strong>and</strong> pH, it was determined that viable runlengths <strong>for</strong> POE AA were likely only when the finished water pH was at or below pH 7.5 (Kempic,2000). Even in this pH range, the media may need to be replaced more frequently than once a year,which would make the option very expensive especially compared to the POU AA option. The runlength data used <strong>for</strong> this analysis were from a site with very little competing ions (Simms <strong>and</strong> Azizian,1997). Studies at other sites with higher levels <strong>of</strong> competing ions have much lower run lengths(Clif<strong>for</strong>d et al, 1998). Based on the limited finished water pH range where POE AA might beeffective <strong>and</strong> that the POU media needs replacing much less frequently due to lower water dem<strong>and</strong>,POE AA has not been listed as a compliance technology. POE devices that utilize media that are lesssensitive to pH adjustment may be listed as compliance technologies in the future once data on theirper<strong>for</strong>mance is generated.However, because the volume <strong>of</strong> water treated by POU AA is much smaller, POU units havetypically have longer run lengths <strong>and</strong> require less frequent replacement than POE units. There<strong>for</strong>e,the costs <strong>of</strong> POU AA treatment were considered in the final rule. The cost <strong>of</strong> replacement <strong>for</strong> POUAA is also much lower than POE AA.5-12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!