Technologies and Costs for Removal of Arsenic From Drinking Water

Technologies and Costs for Removal of Arsenic From Drinking Water

Technologies and Costs for Removal of Arsenic From Drinking Water

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

were based on $40/sq ft). The process areas <strong>for</strong> the design flows in the Very Small SystemsDocument were regressed <strong>and</strong> found to best fit a linear regression:Process Area (sq ft) = 614.6 * Design Flow + 68The process area <strong>for</strong> the conceptual designs in the <strong>Water</strong> Model (6) were also regressed <strong>and</strong>fitted to a linear regression. The conceptual designs covered a design flow range from 0.045to 1.082 mgd. The linear regression from this source is:Process Area (sq ft) = 726.6 * Design Flow + 59The process area estimates using the regression <strong>of</strong> the older model data were selected to makecost estimates <strong>for</strong> buildings, road <strong>and</strong> fence. Since there would be a minimum building size,extrapolating a linear regression below the lowest data point does not create a significantproblem with the intercept. These process area estimates were larger than the process areaestimates from the Very Small Systems Document <strong>for</strong> design flows larger than 0.09 mgd. Atthe lower design flows, the process area estimates were slightly lower using the <strong>Water</strong> Model.The <strong>Water</strong> Model covered a broader range <strong>of</strong> design flows, so less extrapolation is requiredat higher design flows than would be the case if the Very Small Systems Document equationwere used. Another factor that also adds to the conservative nature <strong>of</strong> the process areaestimates is that the data are based on a design that includes regeneration. The space devotedto chemical feeders <strong>and</strong> storage tanks <strong>for</strong> regeneration <strong>of</strong> the media is unnecessary in thisdesign. The process area estimates were compared with the minimum area needed <strong>for</strong> thevessels using the vessel diameter. The process area estimates are greater than three times theminimum area estimates <strong>for</strong> the vessels, including the redundant column.14. The building cost to house the activated alumina system is $45.38/sq ft <strong>for</strong> design flows at orbelow 0.65 mgd. The following equation is used <strong>for</strong> design flows between 0.65 <strong>and</strong> 1 mgd:Building cost = 54.204 * Process Area + 14887D-9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!