12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Disconnect SwitchesType VB Panelboard UnitsFusible Units For SB1, SB2 Switchboards and F1, F2 PanelboardsSelection4DISCONNECTSWITCHESCatalog Numbering SystemV 7 E 3 2 3 3▲ ▲ ▲ ▲ ▲ ▲ ▲Vacu-BreakUnitWidth2 = 12" 7 = 17" M = 17" (Main)HeightA = 2 1 ⁄2" B = 5" E = 7 1 ⁄2" F = 10" H = 15" S = 18.75"Number of Poles2 3Voltage Rating2 = 240V 6 = 600VAmperes0 = Single UnitDouble 1 = 30A 2 = 60A 3 = 100A 4 = 200AAmpere Rating1 = 30A 2 = 60A 3 = 100A 4 = 200A 5 = 400A 6 = 600AExample: V7E3233 = Vacu-Break Unit, 17" Wide, 7 1 ⁄2" High, 3-Pole, 240 Volts, Double Branch Unit with 100 Amp Rating each side. Suffixletters MS indicate Main Switch.Vacu-Break ® Fusible Units2-Pole , 12" Wide240V AC, 250V DCAmpereUnitHeightUnitDepthHorse<strong>power</strong> Rating240 Volt AC250 Volt Lug Wire Range (Cu/AI)UnitWeight Catalog ListRating (inches) (inches) Standard Maximum DC and Cables Per Pole (pounds) Number Price $130–30 2 1 ⁄2 4 1 ⁄2 01 1 ⁄2 03 05 (1)–#14 to #8 (Cu Only) 15 V2A2211LR■ 588.00130–30 5 4 1 ⁄2 01 1 ⁄2 03 05 (1)–#14 to #8 19 V2B2211LR■ 758.00130–60 5 4 1 ⁄2 01 1 ⁄2–3 03–10 05–10 (1)–#14 to #4 19 V2B2212LR■ 837.00160–60 5 4 1 ⁄2 03 10 10 (1)–#14 to #4 19 V2B2222LR■ 837.00100 7 1 ⁄2 6 3 ⁄4 07 1 ⁄2 15 20 (1)–#10 to #1/0 14 V2E2203LR■ 671.00200 7 1 ⁄2 6 3 ⁄4 15 — 40 (1)–#6 to 250 kcmil 19 V2E2204LR■ 1175.003-Pole240V AC, 250V DCAmpereUnitHeightUnitDepthHorse<strong>power</strong> Rating240 Volt ACLug Wire Range (Cu/AI)UnitWeight Catalog ListRating (inches) (inches) Standard Maximum and Cables Per Pole (pounds) Number Price $Branch Circuits, 12" Wide Units130–30 2 1 ⁄2 4 1 ⁄2 03 07 1 ⁄2 (1)–#14 to #8 (Cu Only) 5 V2A3211■ 652.00130–30 5111 4 1 ⁄2 03 07 1 ⁄2 (1)–#14 to #8 9 V2B3211■ 943.00130–30 5111 4 1 ⁄2 03 07 1 ⁄2 (1)–#14 to #8 9 V2B3211R ■ 1007.00130–60 5111 4 1 ⁄2 03–7 1 ⁄2 07 1 ⁄2–15 (1)–#14 to #4 9 V2B3212■ 943.00130–60 5111 4 1 ⁄2 03–7 1 ⁄2 07 1 ⁄2–15 (1)–#14 to #4 9 V2B3212R ■ 1007.00160–60 5111 4 1 ⁄2 07 1 ⁄2 15 (1)–#14 to #4 9 V2B3222 943.00160–60 5111 4 1 ⁄2 07 1 ⁄2 15 (1)–#14 to #4 9 V2B3222R ■ 1007.00100 7 1 ⁄2 6 3 ⁄4 15 30 (1)–#10 to #1/0 14 V2E3203 758.00200 10 11 6 3 ⁄4 25 60 (1)–#6 to 250 kcmil 21 V2F3204 1473.00Main Switch , 12" Wide Units, Back Connected200 10 6 3 ⁄4 25 50 21 V2F3204MS■ 1473.00For inches / millimeters conversion, multiply inches by 25.4.■ Built to order. Allow 2–3 weeks for delivery. These units are available in LR (left, right) connectionfigurations only. This unit is not a Vacu-Break unit, but rather operates on asliding contact, double break principle. Rated 10,000 AICmax. with either Class H or K fuses. Will not accept Class Rfuse clip kits. Units set up for R-fuse application only. For 2-pole main switch (200A), use 3-pole main switchVacu-Break unit. Load-side furnished with spade type bolted terminal pads.4-18<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule VBSS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!