12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Meter CentersModular Metering: Main Switch Service Entrance ModulesFeaturesSelection▪ 400-800Amp Standard Switches (Non-EUSERC) are invertible for top orbottom feed▪ 1200Amp device uses a molded case switch (looks like a breaker)▪ All switches are setup for class T fuses2METERCENTERS▪ 100,000 AIC Rating▪ Small Compact Size▪ Bus Duct entry available for 400-800Amp standard switches, seepage 2-83400 Ampere FusibleSwitch Module800 Ampere Fusible Switch &Pullbox Combination ModuleCheck local utility requirements prior to installation.Fusible Switch ModulesMaximum Outdoor Enclosure Line Terminal Lugs Dimensions (inches) Ampere Interrupt Catalog List Service No. & Size PerRating Rating Number Price $ Fuse Type Feed Line & Neutral Height Width Depth KO Fig.1-Phase, 3-Wire SN, Incoming, 120/240V AC Max.200 100,000 WMP02U 1343.00 T OH (1) #6-250 kcmil 33.00 12.00 13.00 A3400 100,000 WMS4U 4086.00 T OH/UG (2) #4-500 kcmil 35.50 15.00 16.00 A1A600 100,000 WMS6U 7762.00 T OH/UG (2) #4-500 kcmil 41.50 15.00 16.00 A1B800 100,000 WMS8U 11895.00 T OH/UG (3) #4-500 kcmil 41.50 15.00 16.00 A1C1200 100,000 WMS12U 25514.00 T UG (4) #250-500 kcmil 50.00 20.00 15.00 A1D3-Phase, 4-Wire SN, Incoming, 240V AC Max.200 100,000 WMP024U 2043.00 T OH/UG (1) #6-250 kcmil 33.00 12.00 13.00 A3400 100,000 WMS44U 4643.00 T OH/UG (2) #4-500 kcmil 35.50 15.00 16.00 A1A600 100,000 WMS64U 9480.00 T OH/UG (2) #4-500 kcmil 41.50 15.00 16.00 A1B800 100,000 WMS84U 17269.00 T OH/UG (3) #4-500 kcmil 41.50 15.00 16.00 A1C1200 100,000 WMS124U 28611.00 T UG (4) #250-500 kcmil 50.00 20.00 15.00 A1DCombination Fusible Switch & Pull Box Modules (Meets EUSERC Requirements)Maximum Outdoor Enclosure Line Terminal Lugs Dimensions (inches) Ampere Interrupt Catalog List Service No. & Size PerRating Rating Number Price $ Fuse Type Feed Line & Neutral Height Width Depth KO Fig.1-Phase, 3-Wire SN, Incoming, 120/240V AC Max.400 100,000 WMS4UPBU 5005.00 T UG 1 Set of 2 Studs 50.06 25.50 15.00 A2A600 100,000 WMS6UPBU 9260.00 T UG 2 Set of 2 Studs 50.06 25.50 15.00 A2A800 100,000 WMS8UPBU 13374.00 T UG 3 Set of 2 Studs 50.06 25.50 15.00 A2A3-Phase, 4-Wire SN, Incoming, 240V AC Max.400 100,000 WMS44UPBU 6842.00 T UG 1 Set of 2 Studs 50.06 25.50 15.00 A2A600 100,000 WMS64UPBU 12161.00 T UG 2 Set of 2 Studs 50.06 25.50 15.00 A2A800 100,000 WMS84UPBU 20000.00 T UG 3 Set of 2 Studs 50.06 25.50 15.00 A2A Dimensions shown are representative of outside boxdimensions and do not include allowances for mountingbumps, covers, hubs, or hardware protrusions. Wire range listed is the maximum allowable. Fuses not included. Fusible pull-out switch. Lugs not included. NEMA II Stud Pattern lugs must beinstalled by user or utility. Device uses a molded case switch (looks like a breaker).Class T fuses must be installed in conjuction with themolded case switch for proper operation.2-42<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule RESI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!