6MOLDED CASECIRCUIT BREAKERSWL Power Circuit Breakers — Insulated CaseElectronic Trip UnitsSelection criteria for WL CircuitBreakersThe basic criteria for selecting circuitbreakers is:▪ Maximum Available Short Circuitat the installation point. This valuedetermines the short circuit currentinterrupting rating or short circuitcurrent withstand rating of the circuitbreaker▪ Rated Current In which is to flowthrough the respective circuit breakercontinuously. This value may not begreater than the maximum ratedcurrent of the circuit breaker. The ratedthe rating plug, up to the maximumframe rating▪ Ambient Temperature of the circuitbreaker. This is usually thetemperature inside the cubicle▪ Design of the circuit breaker.Protective Functions of the circuitbreaker. These are determined by theselection of the appropriate trip unitTrip Unit FunctionsGeneralBasic Protective Functions ETU725 ETU727Long-time overcurrent protection L ● ●Short-time delayed overcurrent protection S ● ●Instantaneous overcurrent protection I ● ●Neutral conductor protection N — ●Ground fault protection G — ●Additional FunctionsSelectable neutral protection — ●Defeatable short-time protection ● ●Defeatable instantaneous protection — —Selectable thermal memory — —Zone selective interlocking — —Selectable I2t or fixed short-time delay — — Adjustable instantaneous pick-up — —Selectable I2t or I4t long-time delay — —Adjustable short-time delay and pick-up ● ●Selectable and adjustable neutral protection — —Dual protective setting capability — —Dynamic arc-flash sentry — —Extended instantaneous protection ● ●Parameterization and DisplaysParameterization by rotary switches (10 steps) ● ●Parameterization by communication (absolute values) — —Parameterization by menu/keypad (absolute values) — —Remote parameterization of the basic functions — —Remote parameterization of the additional functions — —Alphanumeric LCD — —Graphical LCD — —Metering FunctionMetering function — —Metering function Plus — —CommunicationCubicleBUS — —Communication via PROFIBUS-DP — —Communication via the MODBUS — —Communication via the Ethernet (BDA) — —● Standard — Not available Optional Fixed, short-time delay only.6-76<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!