12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2METERCENTERSMeter CentersEUSERC Meter Main & Meter Load Centers (100-200A) Single Phase, 3-Wire 240V AC▪ UL listed▪ For overhead and underground feed applications▪ Designed to meet EUSERC standards▪ 22,000 AIC Rated▪ Pad locking provisions on all devices▪ Surface and semi-flush units available - semi flush railsare depth adjustable for 2x6 studs▪ Side hinge door removable by backing out only one screw▪ Load wiring may exit top or bottom▪ Suitable for use only as service entrance equipment▪ RX type hub provision on top endwall, HC type hubprovision on bottom endwall▪ 5th jaw accessory available (ECMC5J)▪ Ring type meter covers▪ Contact local utility to confirm meter socket approval prior to installation▪ See end of section for dimensions and wiring diagramsMM0406L1125SEC (shown)MM0406L1125FEC125A Max, main lug metermain, between the studsconstructionSelectionMM0406L1200SEC (shown)MM0406L1200FEC200A Max, main lug metermain, between the studsconstructionMC0816B1200SCTM (shown)MC0816B1200FCTMMC1224B1100SEC (shown)MC1224B1100FECMC1224B1125SECMC1224B1125FECMC2442B1XXXSEC (shown)MC2442B1XXXFECMC4040B1200SECW (shown)MC3040B1200SECW200A Pump Panel, OH/UGFeed, 8 circuits with feed thrulugs, and provisions for up to50A second main breaker100 and 125 Amp, 12 circuit,between the studsconstruction200 and 225 Amp, 24 circuit,between the studsconstruction200A, Wide Load CenterDesign, Meter ComboAmps Main No. of Max. Dimensions ListMax. Breaker Mounting Spaces Circuits Service Catalog Number Height Width Depth Price $100 Q2100H Flush 12 24 OH/UG MC1224B1100FEC 26 9 ⁄16 14 1 ⁄2 7 1 ⁄2 976.00100 Q2100H Surface 12 24 OH/UG MC1224B1100SEC 26 9 ⁄16 14 1 ⁄2 7 1 ⁄2 976.00100 Q2100H Flush 16 32 OH/UG MC1632B1100FEC 30 9 ⁄16 14 1 ⁄2 7 1 ⁄2 818.00100 Q2100H Surface 16 32 OH/UG MC1632B1100SEC 30 9 ⁄16 14 1 ⁄2 7 1 ⁄2 818.00125 Q2125H Flush 12 24 OH/UG MC1224B1125FEC 26 9 ⁄16 14 1 ⁄2 7 1 ⁄2 1668.00125 Q2125H Surface 12 24 OH/UG MC1224B1125SEC 26 9 ⁄16 14 1 ⁄2 7 1 ⁄2 1667.00125 Q2125H Flush 16 32 OH/UG MC1632B1125FEC 30 9 ⁄16 14 1 ⁄2 7 1 ⁄2 1743.00125 QP, QPH Flush 4 6 OH/UG MM0406L1125FEC 26 9 ⁄16 14 1 ⁄2 7 1 ⁄2 515.00125 QP, QPH Surface 4 6 OH/UG MM0406L1125SEC 26 9 ⁄16 14 1 ⁄2 7 1 ⁄2 515.00200 EQ9985 Surface 8 16 OH/UG MC0816B1200SCTM 40 9 ⁄16 14 1 ⁄2 7 1 ⁄2 1711.00200 NEW EQ9985 Flush 8 16 OH/UG MC0816B1200FCTM 40 9 ⁄16 14 1 ⁄2 7 1 ⁄2 1711.00200 EQ9985 Flush 24 48 OH/UG MC2442B1200FEC 40 9 ⁄16 14 1 ⁄2 7 1 ⁄2 2600.00200 EQ9985 Surface 24 48 OH/UG MC2442B1200SEC 40 9 ⁄16 14 1 ⁄2 7 1 ⁄2 2600.00200 QN, QNH, QP, QPH Flush 4 6 OH/UG MM0406L1200FEC 30 9 ⁄16 14 1 ⁄2 7 1 ⁄2 1756.00200 QN, QNH, QP, QPH Surface 4 6 OH/UG MM0406L1200SEC 30 9 ⁄16 14 1 ⁄2 7 1 ⁄2 1804.00200 QN2200RH Surface 30 40 OH/UG MC3040B1200SECW 32 1 ⁄4 21 5 1 ⁄8 2614.00200 QN2200RH Surface 40 40 OH/UG MC4040B1200SECW 32 1 ⁄4 21 5 1 ⁄8 2923.00225 EQ9986 Flush 24 42 OH/UG MC2442B1225FEC 40 9 ⁄16 14 1 ⁄2 7 1 ⁄2 2856.00225 EQ9986 Surface 24 42 OH/UG MC2442B1225SEC 40 9 ⁄16 14 1 ⁄2 7 1 ⁄2 2856.00 Dimensions shown are representative of outside boxlength, width, and depth and do not include allowancesfor mounting bumps, endwalls, covers, hubs or hardwareprotrusions. Dimensions are subject to change. Main breaker not included. FRK1 - Flush rail kit.2-22<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule RESI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!