Molded Case Circuit BreakersND 1200A Frame Sentron SeriesType HNXD6 Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs)2-Pole3-PoleBlack LabelContinuous600V AC/250V DC600V AC/500V DCCurrent Rating Catalog List@ 40°C Number Price $0900 For 2-pole application use outside HNXD63B900 14794.001000 poles of 3-pole circuit breakerHNXD63B100 14794.001200 HNXD63B120 14794.00Selection/DimensionsType HND6 Interchangeable TripBlack LabelComplete BreakerContinuousUnassembled with Lugs Frame Only Trip Unit OnlyCurrent Rating Catalog List Catalog List Catalog List@ 40°C Number Price $ Number Price $ Number Price $2-Pole 600V AC, 250V DC 08000900For 2-pole application use outside poles of 3-pole circuit breaker100012006MOLDED CASECIRCUIT BREAKERS3-Pole 600V AC, 500V DC 0800 HND63B800 13883.00 MD63T800 3747.000900 HND63B900 16498.00HND63F120 8430.00ND63T900 6362.001000 HND63B100 16498.00 ND63T100 6362.001200 HND63B120 16498.00 ND63T120 6362.00Type CND6 Fuseless Current LimitingRed LabelNon-Interchangeable Trip (Assembled Circuit Breaker)Continuous2-Pole3-PoleCurrent Rating Catalog List@ 40°C Number Price $0900 For 2-pole application, CND63B900■ 20489.001000 use outside poles of CND63B100 20489.001200 3-pole circuit breaker CND63B120 20489.00Shipping WeightsNumber of Number per ShippingPoles Carton Weight (lbs.)ND6, HND6, NXD6, HNXD6, CND6Assembled Breaker (less terminals)2 1 533 1 61.5ND6, HND6 Frame Only2 1 42.253 1 46ND6, HND6 Trip Unit Only2 1 04.53 1 06.5LugsWhen lugs shield NDTS is used.Note: NDTS lug shields are required when oversized lugsTA4P8500 or TA4N8500 are used. The kits includethe NDTS shield.Dimensions (in inches)BreakerType W L D D1ND6, NXD6, HND6,HNXD6, CND6,SND6, SHND6, and9 16 6 8.25SCND6with NDTSlug shield9 24 6 8.25For inches / millimeters conversion, see Application Data section.■ Built to order. Allow 2–3 weeks for delivery.HNXD6 and CND6 circuit breakers are UL Listed forreverse connection applications.2-pole units available in 3-pole width only. When wired as shown on page 6-3, this circuit breaker isUL listed and rated for use on 500V DC ungroundedUPS systems only. HACR rated.6-56<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule MCCB

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!