12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Meter CentersModular Metering: Residential Modules—Ringless StyleFeatures▪ UL Listed for 60/75°C conductors.See equipment markings forapplications▪ Individual split covers with barrellock compatibility▪ Available with and without factoryinstalled horn bypass - field installhorn bypass kit available (#ECHBK)▪ Interconnectable with discontinued“MM” modular metering▪ Factory phased 3ø units saves oninstallation timeSelection▪ Single bolt joint coupler included.Order additional couplers as needed.Use closure plates from main deviceto seal openings for thru bus onside.▪ 200A units UL Listed for use onsystems capable of delivering up to100,000 RMS symmetrical amperesmaximum short circuit currentSeries Tested Systems—Specify<strong>Siemens</strong> Modular Metering equipmentin conjunction with EQ® III or UltimateLoad Centers.2 METERCENTERSWMM3URThree SocketModuleWMM4200URFour SocketModuleCheck local utility requirements prior to installation.1-Phase, 3-Wire SN, Incoming & Outgoing, Ringless Type Gangable Meter StacksThru-Bus Cont. Meter Catalog Number Dimensions Field InstalledRating Amps/ Positions Horn List No List Breaker Maximum 5th Jaw KO(amps) Pos Per Stack Bypass Price $ Bypass Price $ Provision AIC Height Width Depth Assembly Fig.2 WMM2UR 1492.00 WMM2URNJ 1540.00 65,000 32.41 13.44 7.84 ECMM5J A113 WMM3UR 1677.00 WMM3URNJ 1739.00 65,000 41.41 13.44 7.84 ECMM5J A12125 4 WMM4UR 2195.00 WMM4URNJ 2330.00 QP, QPH, HQP 65,000 50.41 13.44 7.84 ECMM5J A131200 5 WMM5UR 2806.00 WMM5URNJ 2935.00 65,000 59.41 13.44 7.84 ECMM5J A146 WMM6UR 3427.00 WMM6URNJ 3744.00 65,000 68.41 13.44 7.84 ECMM5J A152 WMM2200UR 3208.00 WMM22URNJ 1610.00 QPP, QPPH, HQPP, 100,000 36.41 17.44 7.84 ECMM5J A16200 3 WMM3200UR 3451.00 WMM32URNJ 3574.00 HQPPH, QP, 100,000 47.41 17.44 7.84 ECMM5J A174 WMM4200UR 4782.00 WMM42URNJ 4878.00 QPH, HQP 100,000 58.41 17.44 7.84 ECMM5J A183-Phase, 4-Wire SN, Incoming and 1-Phase, 3-Wire SN Outgoing, 5-Jaw Ringless TypeGangable Meter StacksThru-Bus Cont. Meter Catalog Number Dimensions Rating Amps/ Positions Horn List No List Breaker Maximum Stack Phasing KO(amps) Pos Per Stack Bypass Price $ Bypass Price $ Provision AIC Height Width Depth Phases/Sockets Fig.3 WMM34UR 1761.00 WMM34URNJ 1840.00 65,000 41.41 13.44 7.84 1-AB, 1-BC, 1-AC A12WMM44ABUR 2378.00 WMM44ABURNJ 2485.00 QP, 65,000 50.41 13.44 7.84 2-AB, 1-BC, 1-AC A134 WMM44BCUR 2378.00 WMM44BCURNJ 2485.00 QPH, 65,000 50.41 13.44 7.84 1-AB, 2-BC, 1-AC A14125 WMM44CAUR 2378.00 WMM44CAURNJ 2485.00 HQP 65,000 50.41 13.44 7.84 1-AB, 1-BC, 2-AC A14WMM54ABUR 3029.00 WMM54ABUR3NJ 3208.00 65,000 59.41 13.44 7.84 1-AB, 2-BC, 2-AC A145 WMM54BCUR 3029.00 WMM54BCURNJ 3208.00 65,000 59.41 13.44 7.84 2-AB, 1-BC, 2-AC A15WMM54CAUR 3029.00 WMM54CAURNJ 3208.00 65,000 59.41 13.44 7.84 2-AB, 2-BC, 1-AC A151200 6 WMM64UR 3744.00 WMM64URNJ 3774.00 65,000 68.41 13.44 7.84 2-AB, 2-BC, 2-AC A152 — — WMM24AB2URNJ 3363.00 100,000 36.41 17.44 7.84 1-BC, 1-AC A163 WMM34200UR 3649.00 WMM342URNJ 3720.00 100,000 47.41 17.44 7.84 1-AB, 1-BC, 1-AC A17WMM44AB200UR 4657.00 WMM44AB2URNJ 4782.00 QP, QPH, 100,000 58.41 17.44 7.84 2-AB, 1-BC, 1-AC A18200 4 WMM44BC200UR 4657.00 WMM44BC2URNJ 4782.00 HQP, QPP 100,000 58.41 17.44 7.84 1-AB, 2-BC, 1-AC A18WMM44CA200UR 4657.00 WMM44CA2URNJ 4782.00 QPPH, 100,000 58.41 17.44 7.84 1-AB, 1-BC, 2-AC A18— — WMM54AB2URNJ 5399.00 HQPP, 100,000 69.41 17.44 7.84 1-AB, 2-BC, 2-AC A195 — — WMM54BC2URNJ 5399.00 HQPPH 100,000 69.41 17.44 7.84 2-AB, 1-BC, 2-AC A19— — WMM54CA2URNJ 5399.00 100,000 69.41 17.44 7.84 2-AB, 2-BC, 1-AC A19 Dimensions shown are representative of outside boxlength, width, & depth and do not include allowancesfor mounting bumps, endwalls, covers, hubs orhardware protrusions. Order filler plate ECCP3U if using standard 2" widecircuit breaker (QP). NOT for use on 3 phase-4 wire delta systems. Order ECMMI5J for insulated 5th jaw. Max. AIC determined by maximum AIC of tenantbreakers. Higher ratings may be achieved thru approvedseries rating combinations. Only “NJ” suffix should be used within the FloridaMeter Group territory.Discount Schedule RESI <strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog 2-45

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!