12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2METERCENTERSMeter CentersModular Metering: Residential Modules—Ring StyleFeaturesWMM4UFour SocketModuleWMM6USix SocketModule▪ UL Listed for 60/75° C conductors.See equipment markings forapplications▪ 1200 Amp thru bus▪ Interconnectable with discontinued“MM” modular metering▪ Factory phased 3ø units saves oninstallation time▪ 200A units UL Listed for use onsystems capable of delivering up to100,000 RMS symmetrical amperesmaximum short circuit current▪ Single bolt joint coupler included.Order additional couplers asneeded. Use closure plates frommain device to seal openings onside for thru bus.Check local utility requirements prior to installation.Main Breaker PanelSelectionSeries Tested Systems—Specify<strong>Siemens</strong> Modular Meteringequipment in conjunction withUltimate Load Centers.1-Phase, 3-Wire SN, Incoming & Outgoing, Ring Type Gangable Meter StackContinuous Meter Dimensions Field IntalledDuty Amps Positions Catalog List Breaker Maximum 5th JawPer Position Per Stack Number Price $ Provision AIC Height Width Depth Assembly KO Fig.1-Phase 4-Jaw Sockets, 1 Phase-3 Wire Thru-Bus 120/240V AC Max.2 WMM2U 1417.00 65,000 32.41 13.44 7.84 ECMM5J A123 WMM3U 1587.00 65,000 41.41 13.44 7.84 ECMM5J A12125 4 WMM4U 2083.00 QP, QPH, 65,000 50.41 13.44 7.84 ECMM5J A135 WMM5U 2684.00 HQP 65,000 59.41 13.44 7.84 ECMM5J A146 WMM6U 3301.00 65,000 68.41 13.44 7.84 ECMM5J A152 WMM2200U 3157.00 QPP, QPPH, 100,000 36.41 17.44 7.84 ECMM5J A16200 3 WMM3200U 3379.00 HQPP, HQPPH, 100,000 47.41 17.44 7.84 ECMM5J A174 WMM4200U 4657.00 QP, QPH, HQP 100,000 58.41 17.44 7.84 ECMM5J A183-Phase, 4-Wire SN, Incoming and 1-Phase, 3-Wire SN Outgoing, Ring Type Gangable Meter StacksContinuous Meter Dimensions Duty Amps Positions Catalog List Breaker Maximum 5th Jaw Stack Phasing:Per Position Per Stack Number Price $ Provision AIC Height Width Depth Assembly Phases/Socket KO Fig.1-Phase 5-Jaw Sockets, 3 Phase-4 Wire Thru-Bus 208Y/120V AC 1252003 WMM34U 1688.00 65,000 41.41 13.44 7.84 Installed 1-AB, 1-BC, 1-CA A124 WMM44ABU 2254.00 65,000 50.41 13.44 7.84 Installed 2-AB, 1-BC, 1-CA A134 WMM44BCU 2254.00 QP, QPH, 65,000 50.41 13.44 7.84 Installed 2-BC, 1-AC, 1-AB A134 WMM44CAU 2254.00 HQP 65,000 50.41 13.44 7.84 Installed 2-AB, 1-BC, 1-CA A135 WMM54ABU 2908.00 65,000 59.41 13.44 7.84 Installed 1-AB, 2-BC, 2-CA A146 WMM64U 3574.00 65,000 68.41 13.44 7.84 Installed 2-AB, 2-BC, 2-CA A152 WMM24AB200U 3208.00 100,000 36.41 17.44 7.84 Installed 1-BC, 1-CA A163 WMM34200U 3574.00 100,000 47.41 17.44 7.84 Installed 1-AB, 1-BC, 1-CA A174 WMM44AB200U 4556.00 QPP, QPPH, 100,000 58.41 17.44 7.84 Installed 2-AB, 1-BC, 1-CA A184 WMM44BC200U 4556.00 HQPP, 100,000 58.41 17.44 7.84 Installed 2-BC, 1-AC, 1-AB A184 WMM44CA200U 4556.00 HQPPH, 100,000 58.41 17.44 7.84 Installed 2-AB, 1-BC, 1-CA A185 WMM54AB200U 5315.00 QP, QPH, 100,000 69.41 17.44 7.84 Installed 2-AC, 2-BC, 1-AB A195 WMM54BC200U 5315.00 HQP 100,000 69.41 17.44 7.84 Installed 2-AC, 2-AB, 1-BC A195 WMM54CA200U 5315.00 100,000 69.41 17.44 7.84 Installed 2-AB, 2-BC, 1-AC A19 Dimensions shown are representative of outside boxlength, width, & depth and do not include allowancesfor mounting bumps, endwalls, covers, hubs orhardware protrusions. Order filler plate ECCP3U if using standard 2" widecircuit breaker (QP). NOT for use on 3 phase-4 wire delta systems. Order ECMM5IJ for insulated 5th jaw. Max. AIC determined by maximum AIC of tenantbreakers. Higher ratings may be achieved thru approvedseries rating combinations.2-44<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule RESI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!