Medium Voltage EquipmentGM-SGTable 6: Cubicle Dimensions Per Vertical Section DimensionsTypeDimensions in Inches (mm)Height Width Depth Drawout AisleWeight in lbs. (kg)Indoor GM-SG 95.25 (2419) 36.0 (914) 98.5 (2502) 72.0 (1829)recommended 3300 (1497)Shelter-Clad Single-Aisle SGM-SG 114.75 (2915) 36.0 (914) 173.5 (4407) 72.0 (1829)includedShelter-Clad Common Aisle SGM-SG 114.75 (2915) 36.0 (914) 269.0 (6833) 72.0 (1829)included5000 (2268)8900 (4037)13SWITCHGEARAisle-Less Non-Walk-In OGM-SG 113.62 (2886) 36.0 (914) 101.9 (2588) 72.0 (1829)recommended 3950 (1792)Table 7: GMSG Vacuum Circuit Breaker Weight in lbs. (kg) ContinuousCurrent (A)5-GMSG-405-GMSG-2505-GMSG-505-GMSG-3505-GMSG-63Circuit Breaker Type7-GMSG-407-GMSG-50015-GMSG-2515-GMSG-50015-GMSG-4015-GMSG-75015-GMSG-5015-GMSG-100015-GMSG-631200 440 (200) 455 (206) 809 (368) 455 (206) 430 (195) 445 (202) 460 (209) 819 (372)2000 650 (295) 665 (302) 819 (372) 665 (302) 640 (290) 670 (304) 675 (306) 829 (377)3000 665 (302) 670 (304) 824 (375) 675 (306) — 675 (306) 680 (308) 834 (379) Weight does not include circuit breakers, add separately from table 7. Weight estimates are for circuit breaker only. Add 75 lbs (34 kg) if shipped separately packaged. Weight and dimensions are approximate. Add 6” (152 mm) to each end of lineup for aisle extension 12” (304 mm) total. 72” (1829 mm) aisle space recommended allows room for interchange of circuit breakers. Minimum aisle space required for handling circuit breaker withlift truck is 65” (1651 mm). Minimum aisle space required if all circuit breakers are at floor level is 54” (1372 mm). Add for roof overhang.Non-Walk-InShelter-CladRear (cable side) 3.62” (92 mm) 3.62” (92 mm)Front (drawout side) 5.37” (136 mm) 1.5” (38 mm) If indoor switchgear is installed on a raised “housekeeping” pad, the pad must not extend further than 3” (75 mm) from the front of the switchgear to avoidinterference with the use of the portable lift truck. Approximate circuit breaker dimensions in inches (mm) (W X D X H):Net32” (813 mm) X 39” (991 mm) X 36” (914 mm)If packed for shipment separate from switchgear:42” (1067 mm) X 47” (1194 mm) X 43” (1092 mm)13-8<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!