12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

4DISCONNECTSWITCHESDisconnect SwitchesType VB Panel UnitsVacu-Break ® Fusible Units For SB1, SB2 Switchboards and F1, F2 PanelboardsSelectionAmpereUnitHeightUnitDepthHorse<strong>power</strong> Rating480 Volt AC 600 Volt ACLug Wire Range (Cu/AI)UnitWeight Catalog ListRating (inches) (inches) Standard Maximum Standard Maximum and Cables Per Pole (pounds) Number Price $2-Pole, Branch Circuits, 17" Wide Units 600V AC, 250V DC1130–30 17 1 ⁄2 6 3 ⁄4 003 007 1 ⁄2 003 010 (1)–#14 to #8 14 V7E2611LR ■ 1063.001130–60 17 1 ⁄2 6 3 ⁄4 003–5 007 1 ⁄2–20 003–5 020–25 (1)–#14 to #4 14 V7E2612LR ■ 1063.001160–60 17 1 ⁄2 6 3 ⁄4 005 020 010 025 (1)–#14 to #4 14 V7E2622LR ■ 1063.001100 17 1 ⁄2 6 3 ⁄4 010 020 015 040 (1)–#10 to #1/0 14 V7E2603LR ■ 753.001200 10 6 3 ⁄4 025 050 030 050 (1)–#6 to 250 kcmil 21 V7F2604LR ■ 1657.001400 15 10 1 ⁄2 — — — — (1)–#1/0 to 500 kcmil 63 V7H2605MR ◆ 3410.003-Pole, Branch Circuits, 17" Wide Units600V AC, 250V DC1130–30 17 1 ⁄2 6 3 ⁄4 005 015 007 1 ⁄2 020 (1)–#14 to #8 14 V7E3611 1364.001130–30 17 1 ⁄2 6 3 ⁄4 005 015 007 1 ⁄2 020 (1)–#14 to #8 14 V7E3611R 1568.001130 17 1 ⁄2 6 3 ⁄4 005 015 007 1 ⁄2 020 (1)–#14 to #8 14 V7E3601 931.001130–60 17 1 ⁄2 6 3 ⁄4 005–15 015–30 007 1 ⁄2–15 020–50 (1)–#14 to #4 14 V7E3612 1364.001160–60 17 1 ⁄2 6 3 ⁄4 015 030 015 050 (1)–#14 to #4 14 V7E3622 1364.001160–60 17 1 ⁄2 6 3 ⁄4 015 030 015 050 (1)–#14 to #4 14 V7E3622R 1568.001160 17 1 ⁄2 6 3 ⁄4 015 030 015 030 (1)–#14 to #4 14 V7E3602 931.001160–100 17 1 ⁄2 6 3 ⁄4 015–25 030–60 015–30 050–75 (1)–#10 to #1/0 18 V7E3623 1915.001100–100 17 1 ⁄2 6 3 ⁄4 025 060 030 075 (1)–#10 to #1/0 20 V7E3633 1915.001100–100 17 1 ⁄2 6 3 ⁄4 025 060 030 075 (1)–#10 to #1/0 20 V7E3633R 2057.001100 17 1 ⁄2 6 3 ⁄4 025 060 030 075 (1)–#10 to #1/0 14 V7E3603 931.001200–200 10 6 3 ⁄4 050 125 060 150 (1)–#6 to 250 kcmil 40 V7F3644J 3192.001200 10 6 3 ⁄4 050 125 060 150 (1)–#6 to 250 kcmil 21 V7F3604 1736.001200 10 6 3 ⁄4 050 125 060 150 (1)–#6 to 250 kcmil 21 V7F3604R 1808.001 400 15 101 ⁄2 100 250 125 350(1)–#1/0 to 500 kcmil or(2)–#1/0 to 300 kcmil63 V7H3605 4033.001 400 15 101 ⁄2 100 250 125 350(1)–250 to 750 kcmil or(2)–#1/0 to 300 kcmil63 V7H3605750 4033.001600 15 10 1 ⁄2 150 400 200 500 (2)–#4/0 to 500 kcmil 63 V7H3606 4164.003-Pole, Main Switch, 17" Wide Units (Vertical Mount, Top Feed, Front Connected)600V AC, 250V DC1400 18.75 10 3 ⁄8 100 250 125 350 — VMS365T 4033.001600 18.75 10 3 ⁄8 150 400 200 500 — VMS366T 4164.003-Pole, Main Switch, 17" Wide Units (Vertical Mount, Bottom Feed, Front Connected)600V AC, 250V DC1400 18.75 17 11 ⁄16 100 250 125 350 — VMS365B 4033.001600 18.75 17 11 ⁄16 150 400 200 500 — VMS366B 4164.003-Pole, Main Switch, 17" Wide Units, Back Connected600V AC, 250V DC1100 17 1 ⁄2 16 3 ⁄4 125 150 130 150 14 V7E3603MS■ 931.001200 10 16 3 ⁄4 150 125 160 150 21 V7F3604MS■ 1736.001400 15 10 1 ⁄2 100 250 125 350 63 V7H3605MS 4033.001600 15 10 1 ⁄2 150 400 200 500 63 V7H3606MS 4164.003-Pole, Switchboard Units, 21" Wide Units, Front Connected 600V AC, 250V DC1800 25 12 3 ⁄4 200 500 250 500 — 160 VF357TL or BL ❍ 9327.001200 25 12 3 ⁄4 — — — — — 160 VF358TL or BL 9568.003-Pole, Switchboard Units, 21" Wide, Back Connected600V AC, 250V DC1800 25 12 3 ⁄4 200 500 250 500 — 160 VB357TL or BL ■ 8573.001200 25 12 3 ⁄4 — — — — — 160 VB358TL or BL ■ 8993.00■ Built to order. Allow 2–3 weeks for delivery.◆ MR suffix only is available and built to order. Allow 2–3weeks for delivery.❍ BL suffix. Built to order. Allow 2–3 weeks for delivery. Catalog number for 2-pole branch circuit units indicateconnection designation LM, LR or MR (indicating Left,Middle and Right, facing the panel). Unit configured to accept class J fuses only. Also accepts300V Class T fuses when used with TFAK42 adapter kit. Load-side furnished with spade type bolted terminal pads. Suffix “T” or “TL” indicates Top Feed.Suffix “B” or “BL” indicates Bottom Feed. Back connected units are also available. Substitute the letter“B” (back connected) for the letter “F” (front connected)in the prefix of the catalog number. All other featuresare identical. Available as Type MR designation only. Switches set up for R-fuse applications only. Available as Type LR designation only.4-20<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule VBSS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!