12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Factory ModificationsSelectionOrdering InformationAll modifications will consist of <strong>Siemens</strong> standard components as available. Standard equipment dimensions and enclosure constructionmay not apply when certain modifications and special features are added.Catalog Number Suffixes indicate numbers or letters added to the end of a catalog number. Example: 14DSE32BA becomes 14DSE32BAA1.Pilot DevicesEnclosureDescription Modification Class Type Suffix List Price $Start, Stop 14, 17, 18, 36, 37, 40, 83, 84, CLM, CM, LE All A1 200. Forward, Reverse, Stop 22, 25, 26, 43 All Push Buttons High, Low , Stop 30, 32 AllA2 360.E-Stop 14 , 17, 18, 22 , 25, 26, 30 , 32, 36, 37, 40 , 43 All ES 271.Test Push Buttons 83, 84 All K1 200.Hand-Off-Auto14, 17, 18, 36, 37, 40, 83, 84, LE All A3 200. CM, CLM All A3 780.For 24 volt HOA control,20 Amp contactor onlyCM, CLM 1 EM 736.Off-On14, 17,18, 22, 25, 26, 30, 32, 36, 37, 40, 43,83, 84, CLM, CM, LEAll A4 200. Selector Switches Auto-Off 14, 17, 18, 40, 83, 84, CM, CLM, LE All A6 200. Forward-Off-Reverse 22, 25, 26, 43 AllHigh-Off-Low 30, 32 AllA5 200.Hand-Off-Auto (Keyed) 14, 17, 18, 36, 37, 40, 83, 84, LE, CLM, CM All A9 601. Auto-Off-Low-High 30, 32 All A0 227.16CONTROLPRODUCTSPilot LightsLens Red Green GreenColor ➔ Red Green Red Green Red Green Amber White Push-To-Test Push To-Test Push To-TestOn On Control On OnFor/Rev For/Rev OL Power For/Rev For/RevLegend➔ Low/High Low/High Run Run Off Off Tripped On Low/High Low/High OffClass Enclosure Type Suffix ➔ FA FB FC FD FJ FK FL FW FS FT FU 14, 40, 17, 18, 36, 37, 87,88, LE, CLM, CM All 215. 215. 215. 215. 315. 315. 315. 215. 273. 273. 375.22, 25, 26, 30, 32, 43, 83, 84 All 429. 429. 409. 409. 315. 315. 315. 215. 548. 548. 375.NEMA & GeneralPurpose ControlCoil OptionsClass 14, 17, 18, 22, 25, 26, 30, 32, 40, 43, 83 , 84 , 87, 88Controller Size — List Price $Coil LetterVolts 60 HZ Volts 50 HZ Change 00–2 1 ⁄2 3, 3 1 ⁄2 424 Separate Control 24 J120 Separate Control 110 F110–120/220–240 110/190–220 A200–208 — D220–240 190–220 G NC NC NC277 240 L220–240/440–480 190–220/380–440 C440–480 380–440 H575–600 550 E24VS DC Coil 48V U125VV156. 302. 402.250VWCoil Letter Controller Size 4 (Vacuum Only)AC (50–60 HZ) or DC Change Size 5 & 6 (ALL)23–26V J42–48V U110–127V F200–220V D220–240V G NC240–277V L380–420V K440–480V H575–600V EMiscellenious OptionsOmit Alternator(deduct)Duplex with SeparateRelay AlternationDuplex with lead pumptransfer switchChange the ListClass 92 to Price $83, 84 95 222.83, 84 93 NC83, 84 94 NC Not Available on Class 14, 40, 22, 43, 30 (size 00–4) andClass LE, CLM (20–30amp) NEMA 1 clamshell enclosures. DC coils include 1 NC, late break aux. contact. This aux.contact takes up one side of the starter (00–4 only). Price x 2 for Classes 22, 25, 26, 30, 32, 43, 83, 84. Bimetal OL - Size 00 - 2 1/2 available. Solid-state OL -Size 00 - 4, 7 & 8 available. For Class 83, 84 two devices are provided. Price x 2. For Class 83, 84 standard enclosure (92) alternatingrelay available in 24V or 120V control only. S coil is not available for size 4 contactors or starters. Class 83 and 84 only.16-94<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule NEMA

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!