12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Totally Integrated PowerCritical Process Monitoring with the 9510/9610<strong>Siemens</strong> Advanced Data Recorder(ADR)For use as a low-cost data concentrator or localdisplay, the 9510 ADR is a multi-function devicewhich supports multiple protocols, digital and I/Ooptions, and customizable displays. Each unitmust be custom configured for your application.Standard units are shipped with displays only forthe digital I/O status. To use the unit as a LocalDisplay, custom programming is required.Features:▪ Monitor breaker status changes with 1msresolution▪ Collect, log and scale pulse inputs from water,air, gas, electricity or steam meters▪ Act as an Ethernet Gateway for serial devices▪ Display Modbus slave information locally and viaHTML web pages▪ Log data and e-mail alarms from DownstreamModbus devices▪ Display trip unit data from WL, Static Trip III andSB-EC devices▪ Trigger alarms based on setpoint conditionsLocal Display for WL Power Breaker9510 ADR 9510 ADR WiringCOM 1WL Trip Units (max 16 devices)Selection▪ Consolidate data from multiple devices in a central display.▪ View real-time and breaker status for up to 16 WLbreakers, with 20 points per trip unit.▪ WL Breakers must include a COM 16 module forcommunication capability.▪ Factory configured and installed.▪ View real-time and breaker status for up to 16 Static Trip IIIunits, with 20 points per breaker.▪ SPI-1000 is required for communication between9510 ADR and Static Trip III.9510 ADR Catalog Number ConfigurationDescriptionMonitor Base Unit Type• Monitor with integrated display, and 5 MB logging memory• Monitor with integrated display, and 10 MB logging memory• Monitor without display, with 5 MB logging memory(Transducer version)• Monitor without display, with 10 MB logging memory(Transducer version)Communication• ModbusMeter Catalog Number9510 D C - 2 R T U - B Z Z ADETUCWater, Air, Gas and Steam MonitoringThe Advanced data recorder comes withDigital inputs which can be configured forpulse counting applications where fullutility monitoring is required.Now gas, water, air and steam pulsescan be collected in one unit, logged anddisplayed. Up to 16 digital inputs can beadded.Local DisplayPower Supply• 85-240 Vac/Vdc 1• 20-60 Vdc 28POWERMONITORINGDevice• Remote Transducer Unit R T UCommunication Cards5 Infrared Modem 10Base-T(Selectable) RS485 (Note 1) (Notes 1 & 2) with RJ45 10Base-FLX X X AX X X X BX X X X CX X X X X DX X X X X EX X X X X X FAuxiliary I/O Cards• None (base meter includes 8 digital in & 7 digital out)• 8 Binary Inputs; 4 Analog Inputs 0 to 1 mA• 8 Binary Inputs; 4 Analog Inputs 0 to 20 mA• 8 Binary Inputs; 4 Analog Outputs -1 to 1 mA• 8 Binary Inputs; 4 Analog Outputs 0 to 20 mA• 8 Binary Inputs; 4 Analog Inputs 0 to 20 mA & 4 Analog Outputs 0 to 20 mA• 8 Binary Inputs; 4 Analog Inputs 0 to 1 mA & 4 Analog Outputs -1 to 1 mAZBCDEFGTropicalization Protection• None•YesZTSpecials• Standard (password protected, no locking or sealing)A* Factory Programming Available (contact sales or refer to Engineering Service price list).8-8<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!