12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

8POWERMONITORINGTotally Integrated Power9200 Power Meter SelectionFeatures▪ Use the 9200 Power Meter for basicmetering applications, like sub-billing,cost allocation and tenant monitoring▪ For use in Switchboards to replacemultiple analog meters and rotaryswitches, with less space and wiring▪ Choose between two mounting options,and one of three measurement packages.All units come standard with Modbus/RTURS-485 communication. The 9200 withno display is excellent for low costsub-metering applications inswitchboardsHigh AccuracyMeasurement Method and Accuracy▪ 64 samples per cycle▪ IEC 60687 class 0.5 accuracy▪ 4 quadrant energy and demand▪ Per phase voltage, current, peak currentdemand, watts, VARs, kWh, and more▪ Neutral current, THD, frequency, <strong>power</strong>factor and more▪ Revenue AccurateBuilding Management InterfacePulse Output Option▪ kWh and/or kVARh and/or kVAh pulsing▪ Rated 100mA, 200 VAC/DCSystem IntegrationCommunications▪ Industry standard protocol, ModbusRTU, for use with WinPM.Netsoftware or any Modbus compatiblesystemStandard MeasurementsVoltage (l-n), per phase, avg.Voltage (l-l), per phase, avg.Current, per phase, avg.Meter OptionsEnhanced Package #1Includes standard measurements andadds:Energy,(kWh) Imported/Exported TotalPower, (kW)Total Peak Power Demand (kW)*Current Demand, Avg + Per Phase PeakCurrent Demand, Avg + Per PhaseCurrent, Neutral FrequencyPower Factor, Total9200 Meter Catalog Number ConfigurationDescriptionMeter base unit and diplay optins• Integrated display unit with RS-485 and Modbus RTU communication• Remote display unit with RS-485 and Modbus RTU communication• Non-display unit with RS-485 and Modbus RTU communicationMetering Options• Configured for Volts and Amps per phase and avg.• Configured for Volts and Amps per phase and avg. with Energy/Power,Frequency, PF (package #1)• Configured for Volts and Amps per phase and avg. with Energy/Power,Frequency, PF, KVAR, kVA, andTHD (package #2)Enhanced Package #2Includes all the preceding parametersand adds:Power, (kW) Per Phase*Power Factor, Per PhaseReactive Energy (KVARh) Import/Export*Apparent Energy, (kVAh)*Reactive Power, (kVAR) Per Phase & Total*Apparent Power, (kVA) Per Phase & Total*Reactive Power, (kVAR) Peak Demand*Apparent Power, (kVA) Peak Demand*THD Voltage & Current, Per PhaseEnergy, (kWh) Import/Export Per Phase*Meter Catalog Number9200 D D - 1 Z Z APower Supply• 100-240 Vac / 110-300Vdc 1• 435-530Vac 2• 20-60 Vdc 3Digital Output•None•Two optically isolated Form A outputs for kWh, kVAh or kVARh energypulsingSecurity Options for Revenue Metering• Password ProtectedSpecials•NoneDRTADGZAZAPower Supply▪ 100-240 VAC (50-60 Hz)/110-300 VDC▪ 20-60 VDC (+/-10%)▪ 480 VAC*Meets or exceeds IEC 60687 class 0.5 accuracy.**As represented in SPACE 2000.8-4<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule PDS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!