2METERCENTERSMeter CentersModular Metering: Common Series Rating ChartsSelectionUse the tables below to determine the correct combination of equipment and circuit breakers for the available fault current. Thischart provides series rating information for the most common applications. For a complete series rating chart please contact yourlocal sales office.Residential / Commercial Available Fault CurrentLoad CenterRMS Symmetrical Amps at Service Entrance Metering Branch Branch Circuit120/240 Volts Maximum Modules Circuit Breakers Breakersto 10,000Series MPOU, WMPOUMSU, WMSUQP (15—125A)QPP (125—200A)QP, QPJ, QT, QPF, QEMC, WMCMTBU, WMTBU QP (15—125A)QPP (125—200A)QP, QPJ, QT, QPF, QESeries MSU, WMSUQPH (15—125A)to 22,000MC, WMCQPPH (125—200A)QP, QT, QPF, QEMTBU, WMTBU QPH (15—125A)QPPH (125—200A)QP, QT, QPF, QESeries MSU, WMSU QPH (15—125A)to 42,000MC, WMCHQPP (125—200A)QP, QT, QPF, QEMTBU, WMTBU HQP (15—125A)HQPP (125—200A)QP, QT, QPF, QESeries MSU, WMSUQPH (15—125A)to 65,000MC, WMCHQPP (125—200A)QP, QT, QPF, QEMTBU, WMTBU HQP (15—125A)HQPP (125—200A)QP, QT, QPF, QEto 100,000 Series MSU, WMSU HQPPH (100—200A) 2-pole QP, QT, QPF, QEMTBU, WMTBU HQPPH (100—200A) 2-pole QP, QT, QPF, QECommercialAvailable Fault Current RMSSymmetrical Amps at 120/240Load CenterVolts Maximum 1-phase, Service Entrance Metering Branch Branch Circuit240 Volts Maximum 3-phase Modules Circuit Breakers BreakersSeries MPOU, WMPOUQP (15—125A) 2-poleQP (15—100A) 3-poleMSU, WMSUQPP (125—200A) 2-poleQP, QPJ, QT, QPF, QEto 10,000MC, WMC QJ2 (60—200A) 3-pole QP, QPJ, QT, QPF, QEQP (15—125A) 2-poleQP (15—100A) 3-poleQP, QPJ, QT, QPF, QEMTBU, WMTBU QPP (125—200A) 2-poleQJ2 (60—200A) 3-poleQP, QPJ, QT, QPF, QEQPH (15—125A) 2-poleSeries MSU, WMSU QPH (15—100A) 3-pole QP, QT, QPF, QEMC, WMCQPPH (125—200A) 2-poleto 22,000QJH2 (60—200A) 3-poleQP, QPF, QEQPH (15—125A) 2-poleQPH (15—100A) 3-poleQP, QT, QPF, QEMTBU, WMTBU QPPH (125—200A) 2-poleQJH2 (60—200A) 3-poleQP, QPF, QEQPH (15—125A) 2-poleSeries MSU, WMSU QPH (15—100A) 3-pole QP, QT, QPF, QEMC, WMCHQPP (125—200A) 2-poleto 42,000QJ2-H (60—200A) 3-poleQPHQP (15—125A) 2-poleHQP (15—100A) 3-poleQP, QT, QPF, QEMTBU, WMTBU HQPP (125—200A) 2-poleQJ2-H (60—200A) 3-poleQPQPH (15—125A) 2-poleSeries MSU, WMSU QPH (15—100A) 3-pole QP, QT, QPF, QEMC, WMCHQPP (125—200A) 2-poleto 65,000HQJ2HQP, QT, QPF, QEHQP (15—125A) 2-poleHQP (15—100A) 3-poleQP, QT, QPF, QEMTBU, WMTBU HQPP (125—200A) 2-poleHQJ2HQP, QT, QPF, QESeries MSU, WMSUHQPPH (100—200A) 2-poleQP, QT, QPF, QEHQJ2HQP, QT, QPF, QEto 100,000HQPPH (100—200A) 2-poleQP, QT, QPF, QEMTBU, WMTBU HQJ2H QP, QT, QPF, QE This chart is applicable only with residential unifiedmeter modules. (<strong>Siemens</strong> sockets, 1-phase outgoing)on pages 2-44 thru 2-45. MSU and WMSU fusible switch modules use Class Tfuses only. MPOU and WMPOU pullouts also useClass T fuses.2-40 Service entrance modules may not have suffix Uin number. No overcurrent protection.<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogListed by Underwriters’ Laboratories, Inc., under file#E10848(N).Discount Schedule RESI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!