6MOLDED CASECIRCUIT BREAKERSMolded Case Circuit BreakersJD 400A Frame Sentron SeriesType JXD2-A 240V AC, 2-Pole 250V DC OnlyBlue LabelNon-Interchangeable Trip (Assembled Circuit Breaker without Lugs)Continuous 2-Pole (3-Pole Width) 3-PoleCurrent Rating Catalog List Catalog List@ 40°C Number Price $ Number Price $200 JXD22B200■ 2546.00 JXD23B200 3094.00225 JXD22B225■ 2546.00 JXD23B225 3094.00250 JXD22B250■ 2546.00 JXD23B250 3094.00300 JXD22B300 2546.00 JXD23B300 3094.00350 JXD22B350■ 2546.00 JXD23B350 3094.00400 JXD22B400 2546.00 JXD23B400 3094.00Type JXD6-A 600V AC, 2-Pole 250V DC, 3-Pole 500V DC Blue LabelNon-Interchangeable Trip (Assembled Circuit Breaker without Lugs)200 JXD62B200■ 3184.00 JXD63B200 3764.00225 JXD62B225■ 3184.00 JXD63B225 3764.00250 JXD62B250■ 3184.00 JXD63B250 3764.00300 JXD62B300 3184.00 JXD63B300 3764.00350 JXD62B350■ 3184.00 JXD63B350 3764.00400 JXD62B400 3184.00 JXD63B400 3764.00Type JD6-A Blue LabelInterchangeable TripComplete BreakerContinuous Unassembled with Lugs Frame Only Trip Unit OnlyCurrent Rating Catalog List Catalog List Catalog List@ 40°C Number Price $ Number Price $ Number Price $2-Pole 600V AC, 250V DC (3-Pole Width)200 JD62B200■ 3309.00 JD62T200■ 1859.00225 JD62B225■ 3309.00 JD62T225■ 1859.00250 JD62B250■ 3309.00JD62F400 1324.00JD62T250■ 1859.00300 JD62B300■ 3309.00 JD62T300■ 1859.00350 JD62B350■ 3309.00 JD62T350■ 1859.00400 JD62B400 3309.00 JD62T400 1859.003-Pole 600V AC, 500V DC 200 JD63B200 3953.00 JD63T200 2070.00225 JD63B225 3953.00 JD63T225 2070.00250 JD63B250 3953.00JD63T250 2070.00300 JD63B300 3953.00JD63F400 1694.00JD63T300 2070.00350 JD63B350 3953.00 JD63T350 2070.00400 JD63B400 3953.00 JD63T400 2070.00Interrupting RatingsRMS Symmetrical Amperes (KA)UL 489 AIR (File E10848) IEC 947-2Volts AC Volts DC Volts AC (50/60Hz)Breaker(50/60Hz) 220/240 380/415 500Type 240 480 600 250 500 lcu lcs lcu lcs lcu lcsJXD2-A 065 — — 30 (2-P) — — — — — — —JXD6-A, JD6-A 065 035 025 30 (2-P) 25 (3-P) 065 033 040 20 30 15HJD6-A, HJXD6-A 100 065 035 30 (2-P) 35 (3-P) 100 050 065 33 42 21HHJD6, HHJXD6 200 100 050 — — 200 100 100 50 65 33CJD6-A 200 150 100 50 (2-P) 50 (3-P) — — — — — —Instantaneous Adjustment Trip RangeNominal Instantaneous Values+20% +20%Breaker Ampere Tolerance ToleranceRating Low 2 3 4 5 6 7 High200-300 1250 1430 1610 1790 1960 2140 2320 2500350-400 2000 2290 2570 2860 3140 3430 3710 4000Ordering InformationSelectionComplete Breaker Unassembledwith LugsPrices of JD6, HJD6, and HHJD6breakers include frame, trip andboth line and load lugs (TA2J6500).When ordered by these catalognumbers, the customer will receivethe frame, trip, and lugs separatelypackaged. For applicationsrequiring different lugs, orderindividual items as needed.Complete Breaker Assembled withoutLugsPrices of JXD6, HJXD6, HHJXD6,and CJD6 include frame withnon-interchangeable trip unitinstalled only. Order required lugsseparately. For line and load lugs(TA2J6500) installed, add suffix “L”to catalog number (add 2 times listprice of lugs for each pole).100% RatedTypes JXD6 and HJXD6 breakersare available with 100% ratings.To order add suffix “H” to catalognumber, and 10% to list price.■100% rated JD breakers require theuse of 90°C Cu cable sized at 75°Campacity and lugs TC1J6600or TC2J6500.50°C Applications see page 6-84.400Hz Applications see page 6-84.Lugs For 75°C Wire CablesCatalog per Wire ListNumber Lug Range Price $TA2J6500 1, 2 #3/0-500 kcmil Cu 31.502 #4/0-500 kcmil AlTA1L6750 1 500-750 kcmil Al 76.001 500-600 kcmil CuTC1J6600 1 #3/0-600 kcmil Cu 77.00TC2J6500 1, 2 #3/0-500 kcmil Cu 76.00Compression LugCCL600 1 500 kcmil Cu/Al 150.00■ Built to order. Allow 2–3 weeks for delivery.Type JXD2 and JXD6 circuit breakers are UL Listed forreverse feed applications.When wired as shown on page 6-3, this circuit breaker isUL listed and rated for use on 500V DC ungrounded UPSsystems only.See Note: A, page 6-81.HHJD6 type circuit breakers meet the UL criteria for“current limiting” at 240 and 480V AC. HACR rated.Note: JD frame qualified to UL489 supplement B“NAVAL.” See page 6-84 for additional information.Modifications page 6-84Enclosures Section 5Accessories pages 6-43 and 6-86 to 6-916-40<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule MCCB

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!