Integrated Power Systems Switchboard (Type IPS)Individually Mounted Devices37.50 (953)Unit Space For ComponentsComponentDimensions in inches (mm)Required Minimum MinimumUnit Space Section Width (W) Section Depth (D)P3 Panels 25.00 (635)P1, P2 PanelsTime Clock (Up to 6 in 20" and 25" wide, 37.50 (953) 20.00 (508) 13.75 (349)9 in 32" wide)LCP Lighting Control Panel 25.00 (635)Distribution Transformer (15 KVA)37.50 (953) 20.00 (508)Distribution Transformer (30 - 45 KVA) 25.00 (635)20.00 (508)Distribution Transformer (75 - 112.5 KVA) 37.50 (953) 32.00 (813)Distribution Transformer (150 KVA)28.00 (711)38.00 (965)Distribution Transformer (225 KVA) 75.00 (1905)Distribution Transformer (300 KVA) 46.00 (1168) 38.00 (965)Lighting Contactor(Up to 4 in 20" and 25" wide,30 through 225 Amp 6 in 32" wide)PLC (LOGO!) (Up to 6 in 20" and 25" wide,20.00 (508) 13.75 (349)ASCO 920 or <strong>Siemens</strong> CLH 9 in 32" wide)PLC (S7–200) (Up to 4 in 20" and 25" wide,6 in 32" wide)Automatic Transfer Switch(up to 400 Amp) 75.00 (1905)32.00 (813) 20.00 (508)400-1200 Amp MCCB1600-2000 Amp MCCB 37.50 (953)800-2000 Amp ICCB (WL Breaker)28.00 (711)2500-4000 Amp ICCB (WL Breaker) 75.00 (1905) 38.00 (965)800-1200 Amp BPS 37.50 (953)1600-2000 Amp BPS38.00 (965)75.00 (1905)2500-4000 Amp BPS 46.00 (1168)12 SWITCHBOARDSNOTE: For required unit space relative to HVAC control and custom specified components, contact <strong>Siemens</strong> sales. These components can be mixed in a 37.5" (953mm) high compartment. 37.50" (half section) for panels that would fit in to panel cans 44". 20.00" for P1/P2 panel (note may be mounted 2 across in >=38" wide sections).25" for P3 panels (note may be mounted 2 across in >=46" wide sections). Distribution transformer minimum size requirements are based on 150 degree rise TP1rated units - aluminum or copper bus. Consult <strong>Siemens</strong> for size requirements related to otherratings including K-Rated. Outdoor sections with transformers must also have rear dooradded to that section for ventilation. Stacked transformers in a section are limited to 45KVAat this time. Contact <strong>Siemens</strong> for updated information. For CLH contactor only, up to 6 in 20"and 25" wide section can be mountedand 9 in a 32" wide section. ATS includes generator controls. Contact <strong>Siemens</strong> sales for details. Emergency <strong>power</strong> generators are available. Contact <strong>Siemens</strong> sales for details.<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog 12-5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!