12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Busway SystemsOffsetsOffsets can be utilized to solve difficult contourproblems and save space. In applications where spacedoes not allow for two connected elbows, a singleoffset can bypass an obstruction. All offsets aresupplied with one joint stack assembly.Selection14BUSWAYSYSTEMSFlatwise Offsets, Dimensions (standard/min.)Dimensions Inches (mm)Ampere Rating *“A” ”B” ”C”AL L-Rated225 — 12 (305) 5 (127) 12 (305)400 — 12 (305) 5 (127) 12 (305)600 — 12 (305) 5 (127) 12 (305)800 400 12 (305) 5 (127) 12 (305)1000 600 12 (305) 5 (127) 12 (305)1200 800 12 (305) 5 (127) 12 (305)1350 1000 12 (305) 5 (127) 12 (305)1600 1200 18 (457) 5 (127) 18 (457)2000 1350,1600 18 (457) 5 (127) 18 (457)2500 2000 18 (457) 5 (127) 18 (457)3000 2500 18 (457) 5 (127) 18 (457)3200 2000 18 (457) 5 (127) 18 (457)4000 3000,3200 24 (610) 8 (203) 24 (610)CU M-Rated225 — 12 (305) 5 (127) 12 (305)400 — 12 (305) 5 (127) 12 (305)600 — 12 (305) 5 (127) 12 (305)800 400 12 (305) 5 (127) 12 (305)1000 — 12 (305) 5 (127) 12 (305)1200 600 12 (305) 5 (127) 12 (305)1350 800 12 (305) 5 (127) 12 (305)1600 1000 12 (305) 5 (127) 12 (305)2000 1200,1350 12 (305) 5 (127) 12 (305)— 16002500 2000 18 (457) 5 (127) 18 (457)3000 — 18 (457) 5 (127) 18 (457)3200 — 18 (457) 5 (127) 18 (457)4000 2500,3000,3200 18 (457) 5 (127) 18 (457)5000 4000 24 (610) 8 (203) 24 (610)Flat RightSuffix OFFRFlat LeftSuffix OFFLEdgewise Offsets, Dimensions (standard/min.)Dimensions Inches (mm)Ampere Rating *“A” ”B” ”C”AL L-Rated225 — 10 (254) 6 (152) 10 (254)400 — 10 (254) 6 (152) 10 (254)600 — 10 (254) 6 (152) 10 (254)800 400 10 (254) 6 (152) 10 (254)1000 600 10 (254) 6 (152) 10 (254)1200 800 10 (254) 6 (152) 10 (254)1350 1000 10 (254) 6 (152) 10 (254)1600 1200 10 (254) 6 (152) 10 (254)2000 1350,1600 10 (254) 6 (152) 10 (254)2500 2000 10 (254) 6 (152) 10 (254)3000 2500 10 (254) 6 (152) 10 (254)3200 2000 10 (254) 6 (152) 10 (254)4000 3000,3200 10 (254) 6 (152) 10 (254)CU M-Rated225 — 10 (254) 6 (152) 10 (254)400 — 10 (254) 6 (152) 10 (254)600 — 10 (254) 6 (152) 10 (254)800 400 10 (254) 6 (152) 10 (254)1000 — 10 (254) 6 (152) 10 (254)1200 600 10 (254) 6 (152) 10 (254)1350 800 10 (254) 6 (152) 10 (254)1600 1000 10 (254) 6 (152) 10 (254)2000 1200,1350 10 (254) 6 (152) 10 (254)— 1600 10 (254) 6 (152) 10 (254)2500 2000 10 (254) 6 (152) 10 (254)3000 — 10 (254) 6 (152) 10 (254)3200 — 10 (254) 6 (152) 10 (254)4000 2500,3000,3200 10 (254) 6 (152) 10 (254)5000 4000 10 (254) 6 (152) 10 (254)*Note: Leg Dimensions A and C have been reversed from prior publications.Edge UpSuffix OFEUEdge DownSuffix OFED14-30<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!