12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Busway SystemsSentron Bus Plug OverviewOverviewSENTRON Bus Plugs are engineeredwith the installer and end user in mind.The installer will benefit from thenumerous features, such as factoryinstalled circuit breakers, compactfootprint, generous wirebend space, anddual interlocks. The end user willappreciate the visible position indicator,as well as the spring loaded pad lockablelatch which prevents access tounauthorized personel.SENTRON Bus Plugs are designed withan interlock device to prevent the doorfrom being opened when the disconnectis on. This also prevents the disconnectfrom being turned on while the door isopen. The interlock ensures that theprotective device is “OFF” prior toinstallation or removal of the bus plug.Once the bus plug is properly installed,a spring - loaded, padlock latch providesadditional security by preventingunauthorized access to the unit.Alignment and interlock stabs arefeatures of the Sentron Bus Plugsengineered to prevent improperinstallation of the unit. Guide stabsprevent installing the bus plug 180degrees out of rotation. In addition, thestabs provide vertical support for verticalapplications. The bus plug ground stabsare designed to ensure positive contactwith both the integral and optionalinternal busway grounds before the busplug fingers contact the phase andneutral bars. Sentron Bus Plugs alsofeature bolt-on mounting to the buswayhousing for secure attachment.Sentron Bus Plugs can be configured forhorizontal or vertical applications. Thefollowing Bus Plugs can be mounted(side by side) five (5) per busway sidechannel (Total 10 per 10' Section).▪ 30-600 SLVBH Fusible (Horizontal) ▪ 30-200 SLVBR Fusible (Riser) ▪ 30-400 Circuit Breaker Sentron SLVB Fusible Bus Plugs featurea direct drive mechanism. The operatinghandle mounts directly to the switchmechanism for fewer moving parts.Enclosure Ratings:▪ IP40▪ IP55Conductors:▪ 3-phase, 3-wire▪ 3-phase, 4-wire▪ 3-phase, 4-wire 200% neutral (400Aand below)Grounding:▪ Integral (Housing)▪ Internal▪ Isolated14 BUSWAYSYSTEMSNote: SLVBH Horizontal Application Shown. Contact <strong>Siemens</strong> for 200% Neutral Applications.<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog 14-23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!