Enclosed Circuit BreakersEnclosures — Knockout and Hub DataKnockouts & Wire Bending SpaceDimensionsTypes 1, 12 and 12KType 3RNumber of Knockouts Per Panel (Type 4, 4X, 12 have no KO’s)Conduit Range Maximum Maximum Cable SizesPer Knockout Hub Size Recommended (Cu/Al)Breaker Outside Dimensions (inches) for Type 1, 3R, 4, 4X,Frame (inches) Top Bottom Side Back Bottom Side Back Type 3R 12 & 12K Enclosures QP, QPH, HQP15–1251⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2 4 4 4 4 3 1 1 2 7 1 ⁄8" high encl. #6 BQ, BQH, HBP 3⁄4, 1, 1 1 ⁄4 1 1 2 2 8 1 3 270–100QPP, QPPH, HQPP125–2251⁄2, 3 ⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2 — — — — 4 1 1 2 1 ⁄2 250 kcmilQJ 1 1 ⁄2, 2, 2 1 ⁄2, 3 2 2 2 2 3 1 1 2 1 ⁄2NGG 3⁄4, 1, 1 1 ⁄4, 1 1 ⁄2, 2, 2 1 ⁄2 — — — — — — — —ED2, ED4, ED6,HED47⁄8, 1 1 ⁄8, 1 3 ⁄8, 1 3 ⁄4, 2 2 2 2 2 2 1 1 27⁄8, 1 1 ⁄8, 1 3 ⁄8, 1 3 ⁄4, 2 2 2 — — 2 — —CED67⁄8, 1 1 ⁄8, 1 3 ⁄8, 1 3 ⁄4, 2, 2 1 ⁄2 2 2 2 2 — 1 12 (CFD6 only 300 kcmil)5ENCLOSEDCIRCUIT BREAKERSFXD6, FD6, FXD6, FD61 1 2 2 1 1 —1 1 ⁄8, 1 3 ⁄8, 1 3 ⁄4, 2, 2 1 ⁄2, 3HFD6, CFD6 1 1 — — 1 — —4JXD2, JXD6, JD6,HJD6, HJXD6, HHJD6, 1 1 ⁄2, 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4 1 1 2 4 — — — 4 (2) 600 kcmilHHJXD6, SJD6, SHJD6LXD6, LD6, HLXD6,HLD6, HHLD6, HHLXD6, 1 1 ⁄2, 2, 2 1 ⁄2, 3, 3 1 ⁄2, 4 1 1 2 4 — — — 4 (2) 600 kcmilSLD6, SHLD6LMXD6, LMD6HLMXD6, HMLD6— — — — — — — — 4 (3) 600 kcmilMD6, SMD6, HMD6(3) 600 kcmil or— — — — — — — — 4ND6, SND6, HND6(4) 500 kcmilHubs (Type 3R)ConduitBreaker Size Catalog ListFrame (inches) Number Price $0 3 ⁄4 ECHS075 39.50QP, QPH, HQP,1 ECHS100 39.50BQ, BQH, HBQ,NGG1 1 ⁄4 ECHS125 39.501 1 ⁄2 ECHS150 39.502 ECHS200 69.001 1 ⁄4 ECHS125 39.50QPP, QPPH, HQPP, 1 1 ⁄2 ECHS150 39.50QJ2, QJH2, QJ2-H 2 ECHS200 69.002 1 ⁄2 ECHS250 109.000 3 ⁄4 ECHR075 40.00ED2, ED4, ED6, 1 ECHR100 39.50HED4, HED6, HHED6, 1 1 ⁄4 ECHR125 39.50CED6 1 1 ⁄2 ECHR150 40.002 ECHR200 70.00FXD6, FD6, HFD6, HFXD6,2 1 ⁄2 ECHV250 125.00CFD6, JXD2, JD6,3 ECHV300 182.00JXD6, HJD6, HJXD6,3 1 ⁄2 ECHV350 274.00LD6, LXD6, HLD6,4 ECHV400 362.00HLXD6(A)Note: Enclosures for 250A max breakershave a hub provision on the rainshed.Enclosures for larger breakers (J, L, M& N frame) have blank toprainsheds. Drill or punch hole in thefield to accommodate hub size desired.For inches / millimeters conversion,see Application Data section.Type 12K only.Type 12K enclosure has no knockouts this location.17 1 ⁄8" high enclosure provides sufficient wire bendingspace for all available CB lugs.Sufficient wire bending space is provided for allavailable mechanical type CB lugs.The use of cables larger than those listed below mayviolate NEC & UL wire bending space requirements.The use of compression type connectors will violateNEC and UL wire bending space requirements.5-14<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product CatalogDiscount Schedule MCCB

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!