Two Speed Heavy Duty StartersEnclosed, Class 30DimensionsFigure 1 Figure 1a Figure 2 Figure 3 Figure 4K2 K1 K3K2K1 K3K1 K2 K3ADADADADGEBGEBGCCEBGK1 K2 K3CEBK3 K1 K2CK3K1K22 Speed 1 WindingNEMA 1 General Purpose Enclosure (Standard width for use with or without CPT)Outline Dimensions Mounting DimensionsMtgApproxScrew Conduit Size Ship WtSize Fig A B C D E G K1 K2 K3 Lbs (Kg) Ref Dwg0–1 3 ⁄4 w/o CPT 1 19 1 ⁄8 (486) 11 3 ⁄8 (289) 7 11 ⁄16 (195) 15 5 ⁄8 (397) 8 1 ⁄4 (210) 1⁄41⁄2– 3 ⁄4 1–1 1 ⁄4 1 1 ⁄2–2 26 (12) D688700–1 3 ⁄4 (200 VA) 1a 24 7 ⁄8 (632) 13 3 ⁄8 (340) 8 1 ⁄8 (206) 21 3 ⁄4 (552) 9 (229) 1⁄41⁄2– 3 ⁄4 1 1 ⁄4 –1 1 ⁄2 2–2 1 ⁄2 52 (24) D688702–2 1 ⁄2 2 16 (406) 17.13 (435) 7.63 (194) 15.25 (387) 14 (355) 1⁄41⁄2– 3 ⁄4 1 1 ⁄4 –1 1 ⁄2 1 1 ⁄4 –1 1 ⁄2 39 (20) D429320013–3 1 ⁄2 2 18.31 (465) 21.19 (538) 7.38 (187) 17.56 (446) 18 (457) 1⁄4 1 1 ⁄4 –1 1 ⁄21⁄2 – 3 ⁄4 1 1 ⁄2–2 60 (27) D72956002NEMA 4/4X Stainless Steel Enclosure (Standard width for use with or without CPT)0–1 3 ⁄4 w/o CPT 3 13 (330) 12 5 ⁄8 (321) 5 3 ⁄8 (137) 12 1 ⁄4 (311) 10 (254) 1⁄4 — — — 34 (15) D419170000–1 3 ⁄4 w/ CPT 3 16 (406) 17 1 ⁄8 (435) 7 5 ⁄8 (194) 15 1 ⁄4 (387) 14 (355) 1⁄4 — — — 47 (21)2–2 1 ⁄2 w/o CPT 3 16 (406) 17 1 ⁄8 (435) 7 5 ⁄8 (194) 15 1 ⁄4 (387) 14 (355) 1⁄4 — — — 47 (21)2–2 1 ⁄2 w/ CPT 3 25 1 ⁄16 (637) 17 3 ⁄16 (437) 7 3 ⁄8 (187) 24 5 ⁄16 (618) 14 (355) 1⁄4 — — — 55 (25)3–3 1 ⁄2 3 29 (737) 23 3 ⁄16 (589) 9 1 ⁄4 (235) 27 1 ⁄2 (699) 20 (508) 5⁄16 — — — 61 (28) D432920014 3 29 (737) 23 3 ⁄16 (589) 9 1 ⁄4 (235) 27 1 ⁄2 (699) 20 (508) 5⁄16 — — — 61 (28) D43292001NEMA 12/3/3R Industrial Use Enclosure (Standard width for use with or without CPT)0–1 3 ⁄4 w/o CPT 3 13 (330) 12 5 ⁄8 (321) 5 3 ⁄8 (137) 12 1 ⁄4 (311) 10 (254) 1⁄4 — — — 34 (15)0–1 3 ⁄4 w/ CPT 3 16 (406) 17 1 ⁄8 (435) 7 5 ⁄8 (194) 15 1 ⁄4 (387) 14 (355) 1⁄4 — — — 47 (21) D171500102–2 1 ⁄2 w/o CPT 3 16 (406) 17 1 ⁄8 (435) 7 5 ⁄8 (194) 15 1 ⁄4 (387) 14 (355) 1⁄4 — — — 47 (21) D171500102–2 1 ⁄2 w/ CPT 3 25 1 ⁄16 (637) 17 3 ⁄16 (437) 7 3 ⁄8 (187) 24 5 ⁄16 (618) 14 (355) 1⁄4 — — — 55 (25)3–4 3 29 (737) 23 3 ⁄16 (589) 9 1 ⁄4 (235) 27 1 ⁄2 (699) 20 (508) 5⁄16 — — — 61 (28) D19673000NEMA 4X Fiberglass Enclosure (Standard width for use with or without CPT)0–2 1 ⁄2 4 23.780 (604) 23.780 (604) 6.890 (175) — — 1⁄4 — — — 28 (13) 241398610033–4 4 39.37 (1000) 29.53 (750) 12.60 (320) — — — — — — 241398610042 Speed 2 WindingNEMA 1 General Purpose Enclosure (Standard width for use with or without CPT)Outline Dimensions Mounting DimensionsMtgApproxScrew Conduit Size Ship WtSize Fig A B C D E G K1 K2 K3 Lbs (Kg) Ref Dwg0–2 1 ⁄2 w/o CPT 1 19 1 ⁄8 (486) 11 3 ⁄8 (289) 7 11 ⁄16 (195) 15 5 ⁄8 (397) 8 1 ⁄4 (210) 1⁄41⁄2– 3 ⁄4 1–1 1 ⁄4 1 1 ⁄2–2 30 (14) D688700–2 1 ⁄2 (200 VA) 1a 24 7 ⁄8 (632) 13 3 ⁄8 (340) 8 1 ⁄8 (206) 21 3 ⁄4 (552) 9 (229) 1⁄41⁄2– 3 ⁄4 1 1 ⁄4–1 1 ⁄2 2–2 1 ⁄2 52 (24) D688703–4 w/o CPT 1a 24 7 ⁄8 (632) 13 3 ⁄8 (340) 8 1 ⁄8 (206) 21 3 ⁄4 (552) 9 (229) 1⁄41⁄2– 3 ⁄4 1 1 ⁄4 –1 1 ⁄2 2–2 1 ⁄2 52 (24) D68870NEMA 4/4X Stainless Steel Enclosure (Standard width for use with or without CPT)0–1 3 ⁄4 w/o CPT 3 13 (330) 12 5 ⁄8 (321) 5 3 ⁄8 (137) 12 1 ⁄4 (311) 10 (254) 1⁄4 — — — 34 (15)0–1 3 ⁄4 w/ CPT 3 16 (406) 17 1 ⁄8 (435) 7 5 ⁄8 (194) 15 1 ⁄4 (387) 14 (355) 1⁄4 — — — 41 (19)2–2 1 ⁄2 w/o CPT 3 16 (406) 13 1 ⁄4 (337) 6 (152) 15 1 ⁄4 (387) 11 (279) 1⁄4 — — — 41 (19)2–2 1 ⁄2 w/ CPT 3 16 (406) 17 1 ⁄8 (435) 7 5 ⁄8 (194) 15 1 ⁄4 (387) 14 (355) 1⁄4 — — — 41 (19)3–3 1 ⁄2 w/o CPT 3 25 1 ⁄16 (637) 17 3 ⁄16 (187) 7 3 ⁄8 (187) 24 5 ⁄16 (618) 14 (355) 1⁄4 — — — 55 (25)3–3 1 ⁄2 w/ CPT 3 29 (737) 23 3 ⁄16 (589) 9 1 ⁄4 (235) 27 1 ⁄2 (699) 20 (508) 5⁄16 — — — 61 (28) D432920014 3 29 (737) 23 3 ⁄16 (589) 9 1 ⁄4 (235) 27 1 ⁄2 (699) 20 (508) 5⁄16 — — — 61 (28) D43292001NEMA 12/3/3R Industrial Use Enclosure (Standard width for use with or without CPT)0–1 3 ⁄4 w/o CPT 3 13 (330) 12 5 ⁄8 (321) 5 3 ⁄8 (137) 12 1 ⁄4 (311) 10 (254) 1⁄4 — — — 34 (15)0–1 3 ⁄4 w/CPT 3 16 (406) 17 1 ⁄8 (435) 7 5 ⁄8 (194) 15 1 ⁄4 (387) 14 (355) 1⁄4 — — — 41 (19) D171500102–2 1 ⁄2 w/o CPT 3 16 (406) 13 1 ⁄4 (337) 6 1 ⁄8 (156) 15 1 ⁄4 (387) 11 (279) 1⁄4 — — — 41 (19)2–2 1 ⁄2 w/CPT 3 16 (406) 17 1 ⁄8 (435) 7 5 ⁄8 (194) 15 1 ⁄4 (387) 14 (355) 1⁄4 — — — 41 (19) D171500103–3 1 ⁄2 w/o CPT 3 25 1 ⁄16 (637) 17 3 ⁄16 (187) 7 3 ⁄8 (187) 24 5 ⁄16 (618) 14 (355) 1⁄4 — — — 55 (25)3–4 w/CPT 3 29 1 ⁄16 (738) 23 3 ⁄16 (589) 9 1 ⁄4 (235) 27 9 ⁄16 (700) 20 (508) 5⁄16 — — — 61 (28) D19673000NEMA 4X Fiberglass Enclosure (Standard width for use with or without CPT)0–2 1 ⁄2 4 23.780 (604) 23.780 (604) 6.890 (175) — — 1⁄4 — — — 28 (13) 241398610033–4 4 39.37 (1000) 29.53 (750) 12.60 (320) — — — — — — 2413986100416 CONTROLPRODUCTSNEMA & GeneralPurpose ControlNote: Dimensions in inches (mm). Dimensions for reference, not for construction. Contact sales office for dimensions not listed.<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog 16-123

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!