12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

PanelboardsType P3 Panelboard Modifications and AdditionsEnclosuresExtra Gutter toSides or Ends of the CanListDescription Price $6" end gutter . . . . . . . . . . . . . . . . . . . . . 235.2" side gutter . . . . . . . . . . . . . . . . . . . . . 200.Barrier in gutter (add to extragutter price) . . . . . . . . . . . . . . . . . . . . 200.Hinged trims . . . . . . . . . . . . . . . . . . . . . 160.Piano hinged trims . . . . . . . . . . . . . . . . 360.Door-in-door trims . . . . . . . . . . . . . . . . 360.Screw to the box trims . . . . . . . . . . . . . 160.Trim mounted devices . . . . . . .See page 10–72• Pilot lights• Toggle switches• Push buttons(Devices mounted and wired to the trim shouldalso have hinged trim specified)Painted boxes . . . . . . . . . . . . See page 10–72Custom colors . . . . . . . . . . . See painted boxesIncrease gauge trimsand boxes . . . . . . . . . . . . . See page 10–72Stainless steel trimsand boxes, Type 1 . . . . . . See page 10–72Aluminum trimsand boxes, Type 1 . . . . . . See page 10–72Meters(Contact sales for pricing and applicationengineering for space requirements)Panel Skirts See page 10-73Special LocksTEY . . . . . . . . . . . . . . . . . . . . . . . . . . . 235.TEU1 . . . . . . . . . . . . . . . . . . . . . . . . . . 255.Cat 60 . . . . . . . . . . . . . . . . . . . . . . . . . 235.LL803 . . . . . . . . . . . . . . . . . . . . . . . . . 235.LL806 . . . . . . . . . . . . . . . . . . . . . . . . . 235.Yale 47 (NYC) . . . . . . . . . . . . . . . . . . . 425.Panel Bus ModificationsCatalogAmperes RatingMain Bus Number 125A 250A 400A 600A750 A/SI AL. B 190. 190. 340. 645.Copper (tin pltd.) F 340. 340. 910. 1335.Copper (silver pltd.) E 455. 455. 475. 1220.1000 A/SI Copper(tin pltd.)G 730. 730. 1020. 2110.1000 A/SI Copper(silver pltd.)H 1070. 1070. 1240. 2355.Subfeed, Feed-Thru and Split BusAmpereList Price $ConnectorRating 3-Pole 2-Pole Cu/Al Wire RangeSubfeed (Double) Lugs for Main LugPanelboards Only225/250 85. 85. (2)—#6 AWG-350kcmil400 235. 235. (2)—250 kcmil(1)—600 kcmilFeed-Thru Lugs — Cannot Be Used inConjunction with TVSS or SubfeedBreakersSee page 10-40 for unit space addersand compatibility with other options.225/250 190. 160. (1)—#6 AWG-350kcmil400 490. 445. (2)—250 kcmil(1)—600 kcmil600 720. 680. (2)—250-500 kcmil800 770. — (2)—600 kcmilSplit Bus225/250 245. 180. (1)—#6 AWG-350kcmil(2)—250 kcmil400 490. 445. (1)—600 kcmil600 720. 680. (2)—250-500 kcmil800 1435. 1390. (2)—600 kcmilBranch and Main Breaker AccessoriesSee page 10-70 and Breaker Section• Handle blocks• Handle locks• Aux. Contacts • UVR Increase capacity neutral up to 200%Main Bus Amps List Price Adder $125 340.250 530.400 560.600 625.See page 10-40 for unit space addersand compatibility with other options.Copper MLO OnlyMain Bus Amps List Price Adder $125 115.250 190.400 285.600 285.SelectionBus mounted TVSS. . . . . . . . . . . . See Section 9 for TPS1Service Entrance LabelType P3 Panelboards are factory labeledsuitable for use as service entranceequipment when NEC requirements are met.A panelboard cannot have more than sixmain disconnects, unless it is a lighting andappliance branch panelboard. Lighting andappliance branch panelboards are limited totwo main disconnects.Grounding of PanelboardsGround Bars except for brazed to box areshipped with the panel interior factorymounted.• Non-Insulated Equipment Ground Bar – STD• Copper Non-Insulated Ground Bar. . . . . . 40.• Al Insulated Equipment Ground Bar . . . . 40.• Cu Insulated Equipment Ground Bar . . . . 75.• Ground Bar Brazed to Box . . . . . . . . . . . 245.(recommended for painted boxes)Shunt Trip on Main or BranchSee breaker section for list priceadders. BL, BLH, HBL, BQD, ED4,HED4, ED6, HED6, HHED6, QJ2,QJ2H, QJH2, HQJ2H as branch only.BL, BLH, HBL, ED2, ED4, HED4, ED6,HED6, HHED6 uses 1" unit space forshunt trip. All others may be used onmains or subfeeds.QJ2, QJ2-H, QJH2, HQJ2H, ED4, ED6, HED4,HED6, HHED6, FXD6, HFD6, JXD6, JD6, HJD6,HJXD6Time ClocksTime clocks may be mounted in a 23"enclosure to be cable connected to thepanel. Sangamo, Tork or Paragon timeclock can be supplied and mounted inpanelboard cabinet. Adds 12" to panelheight. Mounts in Sub-area.ListDescription Price $Time Clock (1 or 2-pole, singleor double throw contacts;3-pole, single throw)277V maximum with plain dial 1070.Options—Astronomical dial 210.An omitting device 75.Reserve <strong>power</strong> or carryover 2450.Space and mountingprovisions only 540.10 PANELBOARDS Accessories on 1" pole breakers (BL, BQD, ED) will takeunit space.Discount Schedule PBSB <strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog 10-39

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!