12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Molded Case Circuit BreakersInternal AccessoriesFeature CombinationsThe available feature combinations are shown in the chart below. For applications requiring combinationsof features not listed in this chart, consult the sales office for availability.GeneralModules Avail. On ST/ UVT/ Elect.Per Breaker ST/ ST/ AUX/ UVT/ UVT/ ST/ AUX/ Bell Ground Grd faultBreakers Breaker Poles ST AUX ALSW ALSW UVT AUX ALSW ALSW AUX ALSW ALSW Alarm fault w/BellQP, BQ, BL 1 1, 2, 3 1 — — — — — 1,2 — — — — —BQD, CQD, NGG 1 2, 3 1 1/1 — — — — 1,2 1/1 1 — — —QJ 1 3 1 1/1 — — — — 2 — — — — —All ED 1 1, 2, 3 1 1/1,1/2 1/1 1/1/1 1 1/1, 1/2 1/1 1/1/1 1, 2 1/1, 2/1 1 — 1 1All FD 2 2, 3 1 — — — 1 1/1 — — 1, 2 1/1 1 — — —All JD, LD, LMD 2 2, 3 1 1 — — 1 1/1, 1/2 — — 1, 2 1/1, 1/2 1, 2 — — —SJD6, SHJD6, SCJD6,1SLD6, SHLD6, SCLD63 1 1 — — 1 1/1, 1/2 — — 1, 2 1/1, 1/2 1, 2 — — —All MD, ND, PD, RDIncluding Electronic 2 2, 3 1 1/1 — — 1 1/1, 1/2 — — 1, 2 1/1, 2/1 1, 2 — — —trip 1 NC / 1 NO,2 NC / 2 NO,STD 6 3 1 — — — 1 — — — 3 NC / 3 NO, — 1 1 — —4 NC / 4 NO,5 NC / 5 NO,6 NC / 6 NOShunt Trip (ST)One or all critical circuit breakers maybe tripped from a distant control pointby use of a shunt trip device. A shunttrip operates through an auxiliary switchcontact; when the breaker opens, currentis not maintained on the shunt trip coil.Undervoltage Trip (UVT)When voltage drops to a value below 35%of the nominal coil rating, the undervoltagetrip device automatically opens the breaker.The operation is instantaneous, and thecircuit breaker cannot be reclosed until thevoltage returns to 85% of line voltage. Theundervoltage trip, which is continuouslyenergized, must be energized before thecircuit breaker can be closed.Auxiliary Switch (AUX)For applications requiring remote “on” or“off” indication (or electrical interlocking),auxiliary switches are available. Eachswitch comprises an “A” (open whencircuit breaker is open) and a “B” (closedwhen circuit breaker is open) contact witha common connection. (Form C)Alarm Switch (ALSW)The alarm switch contact is closed whenthe circuit breaker is opened automaticallyby an overload, short circuit, shunt trip orundervoltage trip. The alarm switchcontact is open when the circuitbreaker is reset.6MOLDED CASECIRCUIT BREAKERSFor ED Frames For FD Frames For JD and LD FramesFactory assembled onlyIf mechanical interlock is installed, no accessory modulecan be installed in the right pocket.If mechanical interlock is installed, no accessory modulecan be installed.If mechanical interlock is installed, no accessory modulecan be installed in the left pocket.One module per column.<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog 6-85

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!