12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Field Modification KitsNEMA, Reduced Voltage and LightingSelectionFused and Non-Fused Disconnect Switch Kits (Includes load base plus line and load fuse clips) Basic Switch Switch Load Base Load BaseSwitch Catalog Catalog Catalog Catalog LugAmpere Number List Number List Kit Number List Number List WireRating Non-Fused Price $ Fused Price $ Description Class J Price $ Class H Price $ Size30 HNB612 77.00 HFB21 84.00 30A, 250V — — HBB21 56.00 #14-2 AWG (Cu/AI)HFB612 137.00 30A, 600V HBB612 81.00 HBB612 81.0060 HNB623 313.00 HFB22 141.00 60A, 250V — — HBB22 83.00 #14-2 AWG (Cu/AI)HFB62 169.00 60A, 600V HBB62 97.00 HBB62 97.00100 HNB623 313.00 HFB63 208.00 100A, 250V — — HBB63 176.00 #14-1/0 AWG (Cu/AI)100A, 600V HBB63 176.00200 HNB64 327.00 HFB64 447.00 200A, 250V — — HBB64 256.00 #6-300 AWG (Cu/AI)200A, 600V HBB64 256.00Class R Fuse Conversion KitsCatalog Number Description List Price $HR21 30A, 240V 83.00HR612 30A, 600V 83.00HR612 60A, 240V 83.00HR62 60A, 600V 83.00HR63 100A, 240/600V 54.00HR64 200A, 240/600V 54.00Hazardous Location Accessories For Enclosure Types 7 & 9Description Conduit Size Inches Catalog Number List Price $Install in bottom as drain.Install in top as breather.Breather/Drain Suitable for Class I groups C & D and 51AADB 41.00 for Class II groups F & G applications only.for 1 ⁄2" NPT.Hole PlugsFor tapered NPT conduit openings.1⁄2 51AAHA 4.20 3⁄4 51AAHB 4.60 1 51AAHC 5.10 1 1 ⁄2 51AAHD 8.20 2 51AAHE 13.80 2 1 ⁄2 51AAHF 21.00 3⁄4– 1 ⁄2 51AARBA 4.20 1– 1 ⁄2 51AARCA 4.60 1 1 ⁄2– 3 ⁄4 51AARDB 10.20 1 1 ⁄2–1 51AARDC 10.20 Cast aluminum, UL Recognized and 2 1 ⁄2– 3 ⁄4 51AARFB 31.00 CSA Certified. Used to reduce existing 2 1 ⁄2–1 51AARFC 29.50 Reducer Bushings tapered NPT conduit opening when 2 1 ⁄2–1 1 ⁄2 51AARFD 25.50 required. 2 1 ⁄2–2 51AARFE 25.50 Conduit Hubs3–1 51AARGC 41.50 3–1 1 ⁄2 51AARGD 41.50 3–2 51AARGE 32.50 3–2 1 ⁄2 51AARGF 32.50 Conduit Controller Enclosure Catalog ListDescription Size Class Size Type Number Price $16 CONTROLPRODUCTSNEMA & GeneralPurpose ControlConduit Hubs For EnclosuresNoncombination - NEMA 12may be field modified for NEMA 3/3R.Combination - NEMA 12 may be fieldmodified for NEMA 3/3R/4 enclosure.Use UL Listed conduit hub forthe appropriate NEMA type.NEMA 3R requires the location of the conduithub to be at a level above the lowest live partand holes of 1/8" dia. to be added in thebottom of the enclosure.Does not apply to class 87 Pump Panels.3⁄4" 49MACML 19.001" 49MACMD 21.00Metal Hub 1 1 ⁄2" All All 12, 3, 3R, 4 49MACMN 26.002" 49MACMF 33.002 1 ⁄2" 49MACMG 72.001" 75D41149001 19.00Metal Hub 1 1 ⁄2" 87 All 3R 75D41149003 19.002" 75D41149004 19.002 1 ⁄2" 75D41149005 19.00 Discount Code: PILO. Discount code: HDSS. For Class R fuses order Class H kit from this table andthe Class R conversion kit.Discount Schedule NEMA <strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog 16-87

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!