12.07.2015 Views

power distribution - Siemens

power distribution - Siemens

power distribution - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

VL Molded Case Circuit BreakersCatalog Numbering SystemSelection/ApplicationInterrupting ClassN — NormalH — HighL — Very HighC — Trip Unit OnlyFrame FamilyG — Type GG L — Type LGE — Type EG M — Type MGD — Type DG N — Type NGF — Type FG P — Type PGJ — Type JGBreaker TypeG — Global (UL, IEC, CE, CSA, NOM)T — Trip Unit Only (Global)H — 100% ratedX — Non-InterchangeableM — Motor Circuit ProtectorS — Molded Case SwitchJ — 240V only rated, Non-interchangeable onlyY — 100% rated, Non-interchangeableN — NavalNumber of Poles1, 2, 3, 4, 5 (4P w/ neutral protection)Trip UnitB — Thermal Magnetic, standard 40° C ambient L — Magnetic Only, Motor Circuit Protector - LowC — Thermal Magnetic, calibrated for 50° C ambient (non-UL) instantaneous rangeD — Electronic w/ LCD, LSI, 3P or 4P (neutral protected) M — Magnetic Only, Motor Circuit Protector - StandardE — Electronic w/ LCD, LSIG, 3P/4W (selectable residual orinstantaneous rangereturn type ground fault protection)N — Electronic LI, 3P or 4P (neutral protected)F — Frame only, without trip unitP — Electronic LSI, 3P or 4P (neutral protected)H — Magnetic only, Motor Circuit Protector - Highinstantaneous rangeS — Molded Case SwitchU — Electronic, LSIG, 3P/4W or 4P, residual ground fault protectionX — Electronic, LIG, 3P/4W or 4P, residual ground fault protection6MOLDED CASECIRCUIT BREAKERSContinuous Current RatingFor GG use 015, 020, 025, 030, 035, 040, 050, 060, 070, 080, 090, 100, 110, 125For EG use 015, 020, 025, 030, 035, 040, 050, 060, 070, 080, 090, 100, 110, 125For DG use 050, 060, 070, 080, 090, 100, 110, 125, 150For FG use 100, 110, 125, 150, 175, 200, 225, 250For JG use 250, 300, 350, 400For LG use 400, 500, 600For MG use 600, 700, 800For NG use 800, 900, 100 (1000A), 120 (1200A)For PG use 120 (1200A), 140 (1400A), 160 (1600A)TerminationsB — Load End Standard (cu/al) LugsL — Line & Load Standard (co/al) LugsX — No Lugs (use only if accessory suffixes are to follow)AccessoriesAuxiliary and Alarm Switch CombinationsSuffix DescriptionA1 — 1 Alarm (includes 1NO & 1NC switch with a 2 Aux./1 Alarm Base, for frames EG to JG) Note: A1 and A3 include 1NO and 1NC switch forA2 — 2 Aux (1NO & 1NC switch with a 3 Aux. Base, for frames EG to JG) alarm purposes, only one of these switches mayA3 — 2 Aux + 1 Alarm (2NO & 2NC switches with a 2 Aux./1 Alarm Base, for frames EG to JG) be used as there is only one space for an alarm.A3 — 2 Aux + 2 Alarm (2NO & 2NC switches with a 2 Aux./2 Alarm Base, for frames LG to PG)A4 — 4 Aux (2NO & 2NC switches with a 4 Aux. Base, for frames LG to PG)Shunt TripsRB — 24 VDC RM — 48-60 VACRC — 48-60 VDC RN — 110-127 VACRD — 110-127 VDC RS — 208-277 VACRE — 250 VDC RV — 380-600 VACUnder Voltage ReleasesUA — 12 VDC UN — 110-127 VACUB — 24 VDC UP — 208 VACUC — 48 VDC UR — 220-250 VACUD — 110-127 VDC US — 277 VACUE — 220-250 VDC UT — 380-415 VACUG — 60 VDC UU — 440-480 VACUV — 600 VACLCD = Liquid Crystal DisplayLS = Long Delay & Short Delay trip functionsLSI = Long Delay, Short Delay, & Instantaneous trip functionsLSIG = Long Delay, Short Delay, Instantaneous, & Ground Fault trip functionsGF = Ground Fault3P = 3-pole4W = 4-wire6-6<strong>Siemens</strong> Power Distribution & Control, SPEEDFAX 2007-2008 Product Catalog

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!